23.7. APPLIANCE START-UP
The start-up must be performed by a qualified technician. Make sure the installation is completed and the oil tank has
been filled up. The oil line must also have been purged.
CAUTION:
CLOSE THE BLOWER COMPARTMENT ACCESS PANEL BEFORE STARTING THE BURNER.
23.8. PROLONGED CLOSING
A) Cut off the electric circuit
B) Close the oil shut-off valve
NOTE: THE SHUT-OFF VALVE MUST BE CLOSED WHEN THE APPLIANCE IS OUT OF SERVICE FOR A
PROLONGED PERIOD OF TIME.
24. TECHNICAL DATA
24.1. UH
–MAX CADDY
MODEL
BURNER
TYPE
BTU
INPUT
NOZZLE
FLOW
HEAD
STATIC
PLATE
PRESSURE
AT THE PUMP
H.P. FAN
MOTOR
TUBULATOR
ADJUSTMENT
AIR
ADJUSTMENT
EFFICIENCY
UH
–
MAX
CADDY
BECKETT AFG
91,000
0.65, 70
0
W
(DELAVAN)
0.65 GAL US/H
(2.46 L-H)
F0
---
100 PSI
(690 kPa)
1/2
---
0/7
85%
UH
–
MAX
CADDY
BECKETT AFG
120,000
0.65, 70
0
W
(DELAVAN)
0.86 GAL US/H
(3.26 L-H)
F0
---
175 PSI
(1205 kPa)
1/2
---
1/6
83%
UH
–
MAX
CADDY
RIELLO 40 F3
91,000
0.50, 70
0
W
(DELAVAN)
0.60 GAL US/H
(2.27 L-H)
---
---
150 PSI
(1035 kPa)
1/2
1
2.5
87%
UH
–
MAX
CADDY
RIELLO 40 F3
120,000
0.65, 70
0
W
(DELAVAN)
0.84 GAL US/H
(3.18 L-H)
---
---
165 PSI
(1135 kPa)
1/2
1
2.5
85%
For any additional information, consult the rating plate on the left hand side of the appliance.
25. MAINTENANCE
At the beginning of heating season, have the complete installation inspected by a qualified service man,
especially the lighting system and the controls.
25.1. MAINTENANCE
WARNING: TURN OFF ELECTRIC POWER SUPPLY BEFORE SERVICING THE UNIT.
1. The furnace, the burner and the flue pipe should be cleaned at least once a year.
2. The nozzle should be inspected and replaced if needed.
3. Handle the nozzle with care to avoid damaging its surface.
4. The electrodes should be adjusted as indicated in the burner manual.
5. Lubricate the burner motor bearings twice a year. (2 or 3 drops of SAE 20 non detergent lubricating oil).
6. The oil filter should be verified annually and replaced if needed.
NOTE: THE UNIT’S MAINTENANCE, REPAIRS AND THE CLEANING OF
THE OIL FILTER MUST BE DONE BY A QUALIFIED TECHNICIAN.
.
Summary of Contents for MAX CADDY PF01102
Page 10: ...10...
Page 47: ...47 15 GENERAL ELECTRICAL DIAGRAM...
Page 48: ...48 16 ELECTRICAL DIAGRAM FOR PARALLEL FURNACE...
Page 49: ...49 17 ELECTRICAL DIAGRAM FOR ELECTRIC UNIT...
Page 55: ...55 22 7 DIFFERENT INSTALLATION...
Page 61: ...61 26 ELECTRICAL DIAGRAM BECKETT OIL UNIT...
Page 62: ...62 27 ELECTRICAL DIAGRAM RIELLO OIL UNIT...
Page 64: ...64 28 4 24V ADDITIONNAL EQUIPMENT 28 5 AIR CONDITIONNING DAMPER 28 6 HUMIDIFIER...
Page 65: ...65 28 7 HEAT PUMP 29 EXPLODED VIEW AND PART LIST...
Page 66: ...66...
Page 67: ...67...
Page 68: ...68...
Page 69: ...69...
Page 70: ...70...
Page 71: ...71...
Page 72: ...72...