PSA LIF6000WB User Manual Download Page 1

1

1

 

Wireless RF interlink baseplate for 
LIFESAVER 6000 series Smoke Alarms. 

You do NOT need a home wi-fi system 
to use these units. Multiple wireless units 
create their own independent wireless RF 
interlink network.

1208-7208-00

Part No: LIF6000WB

RF Interlink Baseplate User Guide

Model 6000WB

Summary of Contents for LIF6000WB

Page 1: ...VER 6000 series Smoke Alarms You do NOT need a home wi fi system to use these units Multiple wireless units create their own independent wireless RF interlink network 1208 7208 00 Part No LIF6000WB RF...

Page 2: ...te their own independent RF interlink alarm network This wireless baseplate is powered by the smoke alarm In the event of a mains power failure the backup battery of the smoke alarm will ensure the wi...

Page 3: ...or To An Existing RF Interlink Network 6 2 3 Resetting The 6000WB 7 2 4 Connecting The 6000WB RF Baseplate to 6000DCW Wireless Smoke Alarms 8 3 Wireless FAQs 9 4 Installation Instruction 11 5 Operatio...

Page 4: ...Operating Range 0 C to 45 C Humidity Operating range up to 95 RH non condensing Smoke Alarm Power 240VAC 50Hz 10mA max 4mA standby Radio Module Power 9VDC from smoke alarm Radio Frequency 918MHz Range...

Page 5: ...er wireless units that connect to the Coordinator General Reset mode Resets a unit to Out of Box condition before it was first powered up 2 1 Setting Up an RF Interlink Network For easy first time set...

Page 6: ...n Mode Red LED flashes three times every 2 seconds to indicate it is configured as a RFD in the network Join Mode will timeout in 15 minutes Step 3 After new unit s have joined press LINK button twice...

Page 7: ...imeout Step 1 Press the LINK button twice on any existing 6000WB or 6000DCW unit The unit will enter Join Mode and flash its Red LED either 1 Twice every 2 seconds denotes Coordinator 2 Three times ev...

Page 8: ...h one second ON and one second OFF After each unit has joined the network its Red LED will flash three times every 2 seconds to indicate it has been configured as a network RFD Join Mode will timeout...

Page 9: ...Network not found The unit will then become a stand alone smoke alarm with no interlink 4 What happens if a Coordinator doesn t find any RFD to join after being set as Coordinator Coordinator times ou...

Page 10: ...rk See Section 2 3 for details 11 Is there a way to get more informa tion about a trouble status In fault mode press LINK button for red LED error code Count the number of Red LED flashes and report t...

Page 11: ...alarm auxilary device unless approved by PSA The earth terminal connection provided is for termination purposes only and is NOT electrically connected within the sealed alarm base units WARNING THIS...

Page 12: ...and void the warranty Terminals on the back of base plate are marked and coloured as follows MARKINGS 9V 9VDC POSITIVE POWER SOURCE A ACTIVE SW SWITCH WIRE FOR INTERCONNECTION ONLY N NEUTRAL LOOP DEA...

Page 13: ...WIRE THE SW TERMINAL OF TWO ALARMS WITH WIRELESS BASE TOGETHER NOTE Smoke alarms can be replaced without replacing the wireless base Active Active Active Neutral Household Cabling Neutral Neutral Swit...

Page 14: ...t may take a few seconds for other interlinked units to alarm WARNING DO NOT USE AN OPEN FLAME TO TEST YOUR ALARM YOU COULD DAMAGE THE ALARM OR IGNITE COMBUSTIBLE MATERIALS AND START A FIRE ACCIDENTAL...

Page 15: ...wiped with a damp cloth After cleaning reinstall your alarm and test your alarm by pressing the Test Button If cleaning does not restore the alarm to normal operation the alarm should be replaced WARN...

Page 16: ...least every six months including fire drills at night Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice allows all occup...

Page 17: ...rms must be tested regularly to ensure the batteries and the alarm circuits are in good operating condition Smoke alarms cannot provide an alarm if smoke does not reach the alarm Therefore smoke alarm...

Page 18: ...of this or Any other warranty express or implied loss or damage caused by failure to abide by the instructions supplied in the leaflets 4 To the extent permitted by law PSA Products Pty Ltd makes no w...

Page 19: ...for warranty to ensure fast and effective service Otherwise please retain this warranty section and complete the details below When you claim Warranty for the product please present this section toge...

Page 20: ...M Another Quality Product By PSA Products Pty Ltd 17 Millicent Street Burwood Victoria 3125 Australia Ph 03 9888 9889 Email enquiry psaproducts com au Webite www psaproducts com au Tested Complies to...

Reviews: