Fixed weight
Activate the "Fixed weight" option if only specific masses (e.g. 2g, 5g,
10g) are available for balancing. Then enter the mass of the "Fixed
weight". VIBXPERT calculates two angular positions at which the two
equal weights must be placed.
Select the "Trial/ Trim masses -> Add" option in the "Tools" menu.
The fixed weight m
fix
must meet the following requirements
relative to the variable weight m
free
:
0.5 x m
free
< m
fix
< 3 x m
free
Measuring tape
The correction mode can determine the position of the balancing
weights with the measuring tape without having to consider a
reference system with angular divisions.
Enter the outer diameter of the rotor in plane A and plane B. The
distance on the outer surface of the rotor is calculated in millimeters
(or inches) from the trigger mark (0° position) and measured counter
to the direction of rotation. Place a tape measure around the rotor
and place the balancing weight at the specified position (i.e. length).
The distance of the balancing weight from the rotational axis is the
balancing radius. This is usually smaller than the outer radius.
In all three correction modes, the calculated specified values can
be changed afterwards. However, the changes should not deviate
significantly from the specified values.
The list in the "Data" field always shows the balancing weights for
the 'Free' correction mode.
Balancing: Options
"Free"
"Fixed weight"
Note
Tape measure length on the
outer surface of the rotor
Balanced radius
External
radius
0° position (trigger mark)
•
Note
Direction of rotation
Left:
"Fixed weight" correction mode
Right:
"Meas. tape" correction mode