Recommended Infrastructure
●
All cabling and wiring shall be UL Listed and/or UL Recognized
●
Refer to Wiring Recommendations for guidance on wire type and length
●
Power Supply- Sufficient to provide 500mA @ 12V DC plus power for door hardware. See door
hardware manufacturer's specifications.
Important:
Edge Reader and Edge Relay can NOT be installed at a distance greater than 30 ft (10 m)
from each other
Wiring Harness Information
Cable colors for Edge Reader Enclosure [5 Core Grey]
Name
Colors
Colors
Sheath Color
UART TX
Green
UART RX
White
5V
Red
3V3
Yellow
GND
Black
Cable colors for Edge Relay Enclosure [5 Core Grey]
Name
Colors
Colors
Sheath Color
UART RX
Green
UART TX
White
5V
Red
3V3
Yellow
GND
Black
|