Proxima Tsunami MP.11 Quick Install Manual Download Page 1

Part Number 69141 

 

Tsunami MP.11 and MP.11a 

Version 2.2

 

Quick Install Guide 

 

 

     

     

 

 

 

 

 

       

 

Summary of Contents for Tsunami MP.11

Page 1: ...Part Number 69141 Tsunami MP 11 and MP 11a Version 2 2 Quick Install Guide ...

Page 2: ...ved by Proxim Corporation could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency ener...

Page 3: ...o Note The installation does not cover the mounting and connection of antennas See the applicable Antenna Installation Guide MP 11 or MP 11a If you are already familiar with this type of product you can use the Quick Install Guide for streamlined installation procedures IMPORTANT Before installing this product see Appendix C of the Installation and Management manual for important regulatory compli...

Page 4: ...ditional information that was not available when this document was printed Installation Procedure To install the MP 11 MP 11a 1 Unpack the unit and accessories from the shipping box The MP 11 MP 11a kit contains the following items Shown in picture 1 Tsunami MP 11 MP 11a unit 2 Mounting stand are CD ROM 3 Documentation and softw 4 Wall mounting hardware 5 Power supply with power cord The shipment ...

Page 5: ... wire to the MP 11 MP 11a using the Faston plug on the metal case next to the power plug 7 Connect one end of an Ethernet cable not supplied to the Ethernet port The other end of the cable should not be connected to another device until after installation is complete º Use a straight through Ethernet cable if you intend to connect the MP 11 MP 11a to a hub switch patch panel or Active Ethernet pow...

Page 6: ...er Be careful to avoid trapping the antenna power and Ethernet cables when replacing the cable cover Attaching a Kensington Security Lock Optional If so desired you can attach a Kensington lock to secure the cable cover into place This protects the unit from unauthorized tampering The MP 11 MP 11a enclosure includes a Kensington Security Slot for use with a Kensington locking mechanism When proper...

Page 7: ... Follow these steps to mount the unit on a wall 1 Identify the location at which you intend to mount the unit 2 If the unit s power supply is plugged in unplug it 3 Use a Phillips screwdriver to remove the metal base from the underside of the MP 11 MP 11a unit if you have not already done so 4 Press down on the cable cover lock to release the cable cover 5 Remove the cable cover from the unit 6 Re...

Page 8: ...g Follow these steps to mount the MP 11 MP 11a to a ceiling 1 If the MP 11 MP 11a s power supply is plugged in unplug it 2 Use a Phillips screwdriver to attach the metal base to the underside of the MP 11 MP 11a if you have not already done so See Installation Procedure on page 4 for an illustration 3 Feed a mounting screw through each of the four rubber feet The MP 11 MP 11a comes with four 3 5 m...

Page 9: ...nt the unit is operational AMBER The unit is initializing after reboot less than two minutes it cannot get a dynamic IP address RED A fatal error in the unit Ethernet Link OFF Not connected GREEN Connected at 10 Mbps BLINKING GREEN Data is being sent at 10 Mbps AMBER Connected at 100 Mbps or the unit is initializing after reboot less than two minutes BLINKING AMBER Data is being sent at 100 Mbps R...

Page 10: ...les as well as image files for embedded software upgrades and you can upload files from the MP 11 MP 11a for backup Here downloading means transferring files to the MP 11 MP 11a and uploading means transferring files in the opposite direction ANTENNA ALIGNMENT DISPLAY Antenna Alignment Display AAD provides a measurement of signal quality in an easy to interpret manner a numeric printed signal valu...

Page 11: ...t cable between the computer and the serial port of the MP 11 MP 11a Ethernet Port To use the CLI through the Ethernet port you must have a telnet program and know the IP address of the MP 11 MP 11a To access the MP 11 MP 11a through Ethernet 1 From the Windows Start menu select Run enter cmd 2 In the DOS window displayed enter the IP address for example telnet 10 0 0 1 3 Click OK to start the tel...

Page 12: ...cted However with Transmit Power Control TPC you can adjust the output power of the unit to a lower level in order to reduce interference from neighboring devices or to use a higher gain antenna without violating the maximum radiated output power allowed for your country MP 11 MP 11a kits sold in the United States are pre configured to scan and display only the outdoor frequencies permitted by the...

Page 13: ...are to which you want to upgrade is supported on your MP 11 MP 11a product To download files to the MP 11 MP 11a click the Commands button and select the Download tab APPLYING CHANGES To apply your changes to the MP 11 MP 11a reboot the device If you do not want to reboot immediately issue the CLI save command to ensure your changes are saved When you do reboot the MP 11 MP 11a is restarted with t...

Page 14: ...cal support please be sure to include the serial number of the product s in question The serial number should be on the product and conform to the following format UT or R7 We will be unable to respond to your inquiry without this information USA Canada Customers Call Technical Support WAN Toll Free 866 674 6626 or 408 542 5390 Hours 6 00 AM to 5 00 PM M F Pacific Time LAN Toll Free 866 674 6626 H...