![ProteOn XPR36 User Manual Download Page 69](http://html1.mh-extra.com/html/proteon/xpr36/xpr36_user-manual_1620131069.webp)
Creating and Editing Protocol Steps
51
The following step types can be dragged from the Step list.
C
OPYING
AND
P
ASTING
P
ROTOCOL
S
TEPS
Two Paste options are available. The Paste option makes a new step using all
the parameters of the object copied but not the sample location. The Paste
Replicate option copies all the parameters of the object copied including the
sample location.
When you select Paste for any step that is not Blank or Regenerate, a new
sample panel is used each time you paste. When you create a Blank or
Regenerate step, the system uses the same sample well until it is empty for
both the Paste and Paste Replicate options.
Step Type
Description
Activate
Activation of the sensor chip surface (for amine coupling GLC, GLM, and
GLH sensor chips only)
Ligand
Control of ligand flow across the sensor chip for immobilization
Deactivate
Deactivation of the sensor chip surface (in amine coupling GLC, GLM, and
GLH sensor chips only)
Regenerate
Regeneration of the sensor chip surface
Analyte
Control of analyte flow across the sensor chip for interaction analysis
Blank
Control of buffer injections across the sensor chip for chip referencing
and equilibration
CoInject Ligand
Sequential injections of ligand
CoInject Analyte
Sequential injections of analytes
Pause
Pause protocol execution. A pause step can be added to a protocol
manually or automatically (to allow wait time for baseline stabilization, for
instance).
Note: In this example, the pause is added manually. An example of an
automatic pause is a step placed into the protocol to allow time to change
the rack or microplate (noninjection step)
Set Temperature
Changes to chip/flow cell temperature in the instrument and recalculates
the SPR reference
Set Buffer
Specifies which of the two running buffers to use for subsequent steps
(noninjection step) and recalculates the SPR reference
Change Rack/
Plate
Allows switching between sample holders at any point in a protocol
(noninjection step)
Summary of Contents for XPR36
Page 1: ...ProteOn XPR36 Protein Interaction Array System Protein Interaction Analysis User Manual...
Page 2: ......
Page 3: ...ProteOn XPR36 Protein Interaction Array System Version 3 1 User Manual...
Page 4: ......
Page 10: ...ProteOn XPR36 System viii...
Page 166: ...ProteOn XPR36 System Analysis 148...
Page 188: ...ProteOn XPR36 Maintenance 170...
Page 194: ...ProteOn XPR36 System ProteOn System Troubleshooting 176...
Page 226: ...ProteOn XPR36 System A ProteOn XPR36 Instrument and Peripherals 208...
Page 250: ...ProteOn XPR36 System E Ordering Information 232...
Page 264: ...ProteOn XPR36 System F Security Edition Configuration Guide 246...
Page 276: ...ProteOn XPR36 System Glossary 258...
Page 287: ......