background image

USE

PRE-USE INSPECTION

Before each use, a person who is going to use  the 

fall arrester

, shall

 

a close visual examination of the retractor’s elements: cover, 

snap hook, handle, working cable or webbing (entire length), must be carried out in respect of mechanical, chemical and thermal 
defects. The user has to check the retractor functioning by dynamic pulling the working cable/webbing. 
The cable/webbing should block and stops pulling out. After releasing the cable/webbing, the retractor should pull in the 
cable/webbing. The examination must be carried out by . In the case of any defect or doubt of correct condition of the 

fall arrester , 

do not use it.

!

personal protective equipment shall only be used by a person trained and competent in its safe use.

!

personal protective equipment must not be used by a person with medical condition that could affect the safety of 
the equipment user in normal and emergency use.

!

a rescue plan shall be in place to deal with any emergencies that could arise during the work.

!

it is forbidden to make any alterations or additions to the equipment without the manufacturer's prior written 
consent.

!

any repair shall only be carried out by equipment manufacturer or his certified representative.

!

personal protective equipment shall not be used outside its limitations, or for any purpose other than that for 
which it is intended.

!

personal protective equipment should be a personal issue item.

!

before use ensure about the compatibility of items of equipment assembled into a fall arrest system. Periodically 
check connecting and adjusting of the equipment components to avoid accidental loosening or disconnecting of 
the components.

!

it is forbidden to use combinations of items of equipment in which the safe function of any one item is affected by 
or interferes with the safe function of another.

!

before each use of personal protective equipment it is obligatory to carry out a pre-use check of the equipment, to 
ensure that it is in a serviceable condition and operates correctly before it is used.

!

during pre-use check it is necessary to inspect all elements of the equipment in respect of any damages, 
excessive wear, corrosion, abrasion, cutting or incorrect acting, especially

 in 

retractable fall arresters - cable or 

webbing, retractor and brake proper acting, casing, energy absorber, connector;

!

regular periodic inspections are the essential for equipment maintenance and the safety of the users which 
depends upon the continued efficiency and durability of the equipment.

!

during periodic inspection it is necessary to check the legibility of the equipment marking. 

!

it is essential for the safety of the user that if the product is re-sold outside the original country of destination the 
reseller shall provide instructions for use, for maintenance, for periodic examination and for repair in language of 
the country in which the product is to be used.

!

personal protective equipment must be withdrawn from use immediately when any doubt arise about its condition 
for safe use and not used again until confirmed in writing by equipment manufacturer or his representative after 
carried out the detailed inspection.

!

a full body harness

 conform to EN 361

 is the only acceptable body holding device that can be used, in a fall arrest 

system.

!

in full body harness use only attaching points marked with big letter "A" to attach a fall arrest system.

!

the anchor device or anchor point for the fall arrest system should always be positioned, and the work carried out 
in such a way, as to minimise both the potential for falls and potential fall distance. The anchor device/point should 
be placed above the user . The shape and construction of  the anchor device/point shall not allowed to self-acting 
disconnection of the equipment. 

I

t is recommended to use certified and marked structural anchor point complied 

with E

N795.

!

it is obligatory 

to 

verify the free space required beneath the user at the workplace before each occasion of use the 

fall arrest system, so that, in the case of a fall, there will be no collision with the ground or other obstacle in the fall 
path. The required value of the free space should be taken from instruction manual of used equipment.

!

there are many hazards that may affect the performance of the equipment and corresponding safety precautions 
that have to be observed during equipment utilization, especially:- trailing or looping of lanyards or lifelines over 
sharp edges,- any defects like cutting, abrasion, corrosion,

!

climatic exposure,- pendulum falls,- extremes of temperature,- chemical reagents,- electrical conductivity.

!

personal protective equipment must be transported in the package (e.g.: bag made of moisture-proof textile or foil 
bag or cases made of steel or plastic) to protect it against damage or moisture.

!

the equipment can be cleaned without causing adverse effect on 

its 

materials. For textile products use mild 

detergents for delicate fabrics, wash by hand or in a machine and rinse in water. Plastic parts can be cleaned only 
with water. When the equipment becomes wet, either from being in use or when due cleaning, it shall be allowed 
to dry naturally, and shall be kept away from direct heat. In metallic products some mechanic parts (spring, pin, 
hinge, etc.) can be regularly slightly lubricated to ensure better operation. Other maintenance and cleaning 
procedures should be adhered to detailed instructions stated in the 

Service M

anual of the equipment.

!

personal protective equipment should be stored loosely packed, in a well-ventilated place, protected from direct 
light, ultraviolet degradation, damp environment, sharp edges, extreme temperatures and corrosive or aggressive 
substances

.

THE ESSENTIAL PRINCIPLES OF USE OF PPE  AGAINST FALLS FROM A HEIGHT

Connecting the fall arrester to a structural anchor point should 
be done by joining the arrester handle to a structure with the 
aid of a connector or sling complying with EN362 or EN795 
standards. The shape of the structural anchor point should not 
let self-acting disconnection of the device. 

It is

 

recommended 

to use cert

i

fied and marked structural anchor point

 

co

nform to

 

EN 795.

 

Connecting the fall arrester to a full body harness 
shoud be done by joining t

he arrester snap hook (placed 

on the end of working cable/webbing) to the frontal or dorsal 
attachment point of full body harness only. Full body harness 
must conform to EN 361. Always protect the gate of the snap 
hook against accidental opening with locking gear.

D

uring use the

 fall arrester should

 be protected from a contact 

with oils, acids, solvents, basics, open fire, hot metal drops and 
sharp edges. During working on the lattice constructions we 
should avoid interleaving the working 

cable/webbing

 between 

the individual construction elements. We should avoid using 
the device in the dust laden and gre

a

sy environment.

The retractable fall arrester shall be installed above the 
operator. 

When the 

device is installed in the vertical line above the user the 
minimal clearence distance below working level shall be 1,5 
m. 
When the cable of the retractable fall arrester is deflected 
from vertical line a pendulum effect occurs during fall 
arresting. In order to minimise the pendulum effect the cable 
deviation angle from vertical shall never exceed 40°.  For this 
purpose the user is permitted to move laterally through 
distance “l” not greater than 1/2 “v” .
The clearance distance bellow working level must be greater 
than 1,5 m+ lateral distance “l”.

Structural anchor point should be situated above 

the job place and have static resistance min. 12kN. 

The retractable fall arresters allowed to horizontal usage and to protection against falls over an edge are specially marked - see 
pictogram description. The  arresters  were successfully tested according to new PPE -Directive 89/686/EEC regulation 
(Document CNB/P/11.060). For roof works the retractable device shall be associated with roof lanyard AZ 800. The equipment 
may be used over such kind of edges as: rolled steel profiles, wooden beams or clad, rounded roof parapet. In case of very 
“cutting type edge or “not free of burrs” (such as unclad roof rusty steel girder or a sharp concrete edge an edge protector should 
be mounted. 

The exact method of use the equipment is described in Instruction Manual of the roof lanyard AZ800.

STRUCTURAL ANCHOR POINT REQUIRMENTS

UTILIZATION  THE  FALL  ARRESTER  FOR  ROOF  WORK

v

retractable type 

fall arrester

retractable type 

fall arrester

anchor point

anchor point

l

z

working 
level

pendulum 
effect

ground 
level

o

max 40