Reference 104S
♦
ProLinx Gateway
Protocol Manual
(Firmware v3.00 and later)
Page 126 of 157
ProSoft Technology, Inc.
January 22, 2010
5.3
Server Error and Status Data
The Driver Error and Status Data areas represent a collection of status, diagnostic
and troubleshooting registers which may prove helpful in troubleshooting the 104S
network and port operation. The data map functionality of the gateway must be
utilized to map this data into the application gateway database area (memory word
addresses 0 to 3999). All or any portion of the data can be moved using the Data
Map.
The data area is initialized with zeros whenever the gateway is initialized. This
occurs during a cold-start (power-on), reset (reset push-button pressed) or a warm-
boot operation (commanded or loading of new configuration).
Status Register Name
Description
10200
t0 Timeout Count
This word contains the number of t0 errors
recognized by the gateway.
10201
t1 Timeout Count
This word contains the number of t1 errors
recognized by the gateway.
10202
t2 Timeout Count
This word contains the number of t2 errors
recognized by the gateway.
10203
t3 Timeout Count
This word contains the number of t3 errors
recognized by the gateway.
10204
Sequence Error Count
This word contains the number of sequence errors
recognized by the gateway. When the send
sequence number received by the gateway does
not match the expected sequence number, the
connection is closed and this counter is
incremented.
10205
Bad Address Error Count
This word contains the number of messages
received from the remote host that do not contain a
valid common ASDU address in the packet.
10206
Length Error Count
This word contains the number of messages
received from the remote host that do not have a
valid length field.
10207
Receive Frame Count
This word contains the number of message frames
(not packets) received from the host. A packet may
contain more than one message.
10208
Transmit Frame Count
This word contains the number of message frames
sent to the host from the unit.
10209
Socket State Value
(socket 0)
This word contains the current socket state as
follows:
-1 = Open Socket
0 = Wait for connection
1 = Transmit message if ready
2 = Receive packet and process message
3 = Process multiple messages in packet
50 = Send TestFr Act
51 = Wait for TestFr Con
60 = Send sequence (S-Format) message
1000 = Close Socket
1001 = Wait for socket to close
10210 Socket
Open
Count
(socket 0)
This word contains the number of times the socket
listen function executed.