Pro'sKit NT-309 Operation Manual Download Page 1

                                                                                                 

 

NT-309    Smart Non-contact Voltage Tester 

Operation Manual 

Warning: Please read and understand all of the instructions 

and safety information in this manual before operating the tester. 

Failure to observe these precautions can result in injury and can 

damage the instrument.   

 

Structural Diagram 

 

 Probe (NCV sensor)     

 Power switch     

 

LED light switch     

 Induced voltage indicator   

 Signal intensity indicator (Low) 

–orange LED   

 Signal intensity indicator (Mid.)-orange LED   

 Signal intensity indicator (High) 

–red LED   

 LED illumination lamp 

 

OPERATING INSTRUCTIONS   

Alternating Voltage Detection 

1. 

Press the power switch to t

urn on the instrument’s power. 

2. 

After  you  confirm  that  the  instrument  is  operating  normally, 
using  it  to  check  whether  an  outlet  and/or  wire  or  cable  is 
energized. 

3. 

If  the  instrument  detects  alternating  voltage,  the  red  light  in 
probe will flash, the beeper will sound, and the relevant signal 
intensity  indicator  (low,  mid,  high)  will  light  up  in  accordance 
with  the  signal  intensity  detected,  and  the  buzzer  makes  the 
different level sound.   
If  the  instrument  detects  (low)  AC  signal,  the  signal  intensity 
indicator  lamp  will  light  up  2  indicators;  if  it  detects  higher  AC 
signal,  the  both  of  signal  intensity  indicator  (low  and  mid)  will 
light up 4 indicators; if it detects highest AC signal, the all signal 
intensity indicators (low, mid, high) will light up. 

4. 

When  finished testing,  remember to  power  off  by  pressing  the 
power  switch  again.  This  will  extend  the  life  of  the  batteries 
powering the unit. 

 

Warning 

1) If the alternating voltage is detected, this indicates the presence of 
voltage,  even  though  there  is  no alarm  indication.  The  presence  of 
voltage  cannot  be  judged  by  the  non-contact  voltage  tester.  The 
detecting  operation  may  be  affected  by  such  factors  as  socket 
design, insulation thickness and insulation type.   

2) 

Before the instrument is used for detecting the alternating voltage 

of the power socket etc, the test pencil should be tested on a known 
live circuit, to make sure that it will work well.

 

 

 

 

Specifications

 

Technical indicators 

NT-309 

Range of alternating voltage 

12 ~1000V 

Frequency

 

50 Hz /60Hz

 

Alarm mode 

Sound and light alarm 

Illumination lamp 

White LED 

Auto power off   

3 minutes 

voltage level indicator 

Low, Medium, High intensity indicator 

Neutral/ live wire judgment 

Sound (different frequency) and LED 
lamp 

NCV sensitivity   

Indicating in 3 level of sensitivity 
automatically (Low, Mid., High) 

NCV sensitivity indication mode 

Audible alarm of different frequency,   
LED lamp of different color to 
indicate low, mid or high sensitivity. 

General parameters   

Power source 

2×1.5V AAA batteries (not included) 

Product size 

156mm×20mm×20mm 

Product weight 

45g 

Security level 

CE    CAT.III 1000V 

Service temperature   

0~40

 

Storage temperature   

-10~50

 

Altitude   

<2000m 

 

Auto Power off 

If  the  instrument  is  not  operated  or  doesn

’t  detect  any  alternating 

voltage more than 3 minutes, it will turn off automatically.   

 
Low  voltage  indicator  lamp

when the battery voltage is 

less than around 2.6V, the power  indicator will flash three times for 
alarm, and the buzzer will sound once before the instrument turns off 
automatically. The battery should be replaced.   

 
LED  light

:  the  LED  light  will  light  up  when  pressing  the  LED  light 

switch  button  and  will  turn  off  when  the  button  is  pressed  again.  If 
this instrument stops operating after 5 minutes, the LED light will go 
out automatically. 

 
Battery Replacement: 

 

1) Rotate the cover to open the battery compartment, 
2) Take out the used batteries, 

3)

 

Replace new 2 x 1.5V AAA batteries as the anode and cathode 

indication as shown on the case. 

 

Warning: To avoid electric shock, do not use this instrument before 
the battery cover is replaced 

 

   

 

 

PROKIT’S INDUSTRIES CO., LTD

   

Email: 

[email protected]

   

http://www.prokits.com.tw

   

©2016 Prokit’s Industries Co., LTD. All rights reserved 2016001(C) 

 