Page 1: ... Manual Promolife Inc 888 742 3404 www promolife com 1 Promolife Inc 1220 S Happy Hollow Road Fayetteville AR 72701 USA 888 742 3404 www promolife com sales promolife com OPERATING MANUAL FOR THE O3ARC AND O3ARC PLUS ...

Page 2: ...ml flow cc min x time min Total Ozone Total Volume ml x Ozone Concentration ug ml Need Support Visit www promolife com support to schedule a setup or support call or contact us through chat email or phone The importance of our quick start procedure The Quick Start Guide is on page 4 We recommend this procedure because when you first turn on an ozone generator the ozone cell is at room temperature As...

Page 3: ...s highly efficient at heat dissipation Most ozone generators have fluctuating ozone outputs especially at lower flow rates This is because the heat dispersion is not designed to handle lower flows By flattening the cell the surface area is more than doubled which provides much more stable ozone production Figure A Ultra Pure Ozone Like our O3Elite ozone generators the O3Arc utilizes alumina oxide cerami...

Page 4: ...generator for use or testing For why we recommend this see the back of this manual 2 After two minutes you may adjust the oxygen and Power settings to reach your chosen concentration 3 When session is complete turn off the ozone generator 4 Wait 15 30 seconds to purge ozone from the lines then turn off the oxygen 5 If the ozone generator is hooked up to a bubbler make sure the generator is higher th...

Page 5: ... Hold 3 Sec POWER ON OFF OZONE OUT OXYGEN IN POWER 12VDC PRESSURE RELIEF VALVE The Standard Model Figure B MODE DOWN UP START Hold 3 Sec POWER ON OFF AUXILLIARY OUT OXYGEN IN POWER 12VDC PRESSURE RELIEF VALVE FOOT PEDAL HOOKUP AUX PORT POWER OZONE OUT The Plus Model Figure C DESTRUCT PORT ...

Page 6: ...is is a normal occurrence and can be expected from time to time AIR FLOW ATTACHES TO OZONE GENERATOR CHECK VALVE AIR FLOW Attaching tubing The ozone generator has female Luer Lock connectors for the Oxygen In Ozone Out and Aux Out ports These are designed to be used with tubing that has a male Luer lock on one side Attach the male Luer Lock with tubing attached to the female Luer Lock and turn clo...

Page 7: ...tration Setting the Timer If the timer is not used ozone will flow continuously To set the timer first select your ozone output then press the Mode button This will switch to Timer Mode MODE DOWN UP START To increase time press the Up Set button To lower the time press the Down button To start ozone production press the Up Start button for three seconds A blue light will illuminate indicating ozone ...

Page 8: ... the built in ozone destruct port of the O3Arc Plus You can use these to fill syringes with a dental handpiece for timed ozone shutoff and more OXYGEN OZONE When the auxilliary port is off ozone exits through the side port When the auxilliary port is on either through a foot switch or Aux Power button ozone exits the AUX port Figure D OXYGEN OZONE ON ...

Page 9: ... ozone from entering the room 2 Auxiliary port access When using the auxiliary port the ozone machine needs to be actively running and producing ozone This will be indicated by the blue light on the right side of the digital display To eliminate excess ozone from flowing into the room simply link the destruct port to the ozone out port on the right side of the ozone generator See Figure D and D 2 T...

Page 10: ...ystem If high pressure occurs inside the ozone generator only oxygen will be released This one of a kind system protects your ozone generator Check Valve Each ozone generator comes with one ozone check valve These will last anywhere from 3 to 6 months depending on use This device is designed to catch liquid from entering the ozone generator We recommend replacing every 3 to 6 months Troubleshootin...

Page 11: ...ks in several seconds your unit is producing ozone There could be humidity or moisture inside your ozone generator To remedy this run oxygen through the unit while the unit is power off Do this for 30 minutes to see if the generator starts to produce ozone again If you are unable to diagnose the issue please contact Promolife ozone generator Using your mouth blow air through the tubing so it enters...

Page 12: ...se of malfunction to be misuse Promolife is not liable to the purchaser or other users for loss of use of the generator or for other special indirect incidental or consequential damages Promolife is not liable for any special indirect incidental or consequential damages that result from the misuse or malfunction of the ozone generator and or any of its components Download our Warranty Repair form ...