VTrak 15200 User Manual
148
--------------------------------------------------------------------------
Logical Drive 2 Parameters:
Name: LogDrv2 RAID Level: 1
Stripe Block Size: 64K Capacity: 35 GB
Member PDs: 3,5 Smart Check: On
Cache Policy: Write Through Retry Count: 2
Auto Rebuilding: On Hot Spare: Global
Priority: High(RBLD), High(SYNC), High(Migration)
SCSI Mapping: CH 1 LUN 1
SCSI Mapping: CH 2 LUN 1
-------------------------------------------------------------------------
Modify Logical Drive Parameters
1. SCSI Assignment
2. Cache Policy
3. Retry Count
4. Enable/Disable SMART
5. Logical Drive Name
6. Priority
7. Hot Spare Policy
8. Auto Rebuilding Option
R. Return to Previous Menu
SCSI Assignment
Use this feature to change the SCSI LUN assignments for a logical drive.
Note:
To hide a logical drive from an iSCSI port, set its LUN to 255.To reveal it,
reset the LUN to one of those listed beside the prompt.
1.
Type 1 and Enter to access SCSI Assignment.
Modify LUN for iSCSI port 1, Logical Drive 2(y/n)?>
y
2.
Type Y and Enter to confirm.
Enter the new LUN (2,3,4,5,6,7,8,9,10,11,12,13,14,15)>
3
LUN is set to 3 for iSCSI port 1 Logical Drive 2
Press Enter key to return
Modify LUN for iSCSI port 2, Logical Drive 2(y/n)?>
n
3.
Type the new LUN for iSCSI port 1 and press Enter.
4.
To change the LUN for iSCSI port 2, press Y and Enter. Then type the new
LUN and press Enter.
To leave the LUN for iSCSI port 2 unchanged, press N and Enter.
5.
To return to the Modify Logical Drive Parameters menu, press Enter.