193
Troubleshooting
Vess A3340 Product Manual
s
tatus
leD
s
Each drive slot on the Vess A3340 has a single corresponding HDD Status LED for,
the LED display is located on the front panel. In addition to these, pay attention to the
System Status and Global RAID LEDs to get an idea of what might be wrong with the
affected hard drive.
Vess A3340 Status LED behavior
HDD Status
One LED for each HDD carrier. Each LED lights GREEN when healthy, RED if the RAID member is
offline or there is a physical disk error, ORANGE indicates the drive is rebuilding, and a dark LED
indicates either no drive is installed or the drive is not configured. A RED LED here means that
drive should be replaced.
System Status
Lights GREEN when healthy, RED if there is a critical problem (LD offline, fan malfunction, voltage
out of range, system temperature alert), blinks RED for HDD high temperature alert remains dark
when not ready. This will be RED if a hard drive has failed or has critical errors. Replace the drive
corresponding to the RED HDD Status indicator.
Global RAID
Status
Lights GREEN when healthy or RED if any RAID volume is offline, ORANGE for critical state of
any logical drive. If a hard drive has failed, this will be ORANGE. In this case, it will be necessary to
replace the affected drive and rebuild the affected RAID volume.
Vess A3340 Left front panel LED
HDD Status LEDs
Global
RAID
System
Status