background image

Pin Assignments

Sensor Input Connector

1

3.3V

2

IN_8 -

3

IN_8 +

4

IN_7 -

5

IN_7 +

6

IN_6 -

7

IN_6 +

8

IN_5 -

9

IN_5 +

10

IN_4 -

11

IN_4 +

12

IN_3 -

13

IN_3 +

14

IN_2 -

15

IN_2 +

16

IN_1 -

17

IN_1 +

18

GND

Pin Number SENSOR IN

3

IO Terminal Board User Information      

Summary of Contents for Vess A2000 Series

Page 1: ...Vess A2000 Series IO Terminal Board User Information Version 1 0 2014 PROMISE Technology Inc All Rights Reserved ...

Page 2: ...tput Connector 4 How to use the I O Receptacle 5 Operation Examples 6 Sensor Input Connection 6 Check Sensor Input Status in CLI7 Alarm Output Connection 8 Enable sensor output in CLI 9 Disable Alarm Device 10 Connecting an Analog Cameras with RS 232 422 485 ports 11 Configure connection in CLI 12 FAQ 14 ...

Page 3: ...tions that PROMISE customers might have concerning the function of the I O terminal board available as an option on the Vess A2000 NVR Storage Appliance models Vess A2200 rear panel Vess A2600 rear panel 1 IO Terminal Board User Information ...

Page 4: ...ce Sensor Input Connector Connect sensor input lines An external device issues a warning to the I O terminal board controller Alarm Output Connector Connect alarm output lines Used to send pre defined alarm signals I O terminal interface 2 Vess A2000 NVR Storage Appliance Promise Technologies ...

Page 5: ...s Sensor Input Connector 1 3 3V 2 IN_8 3 IN_8 4 IN_7 5 IN_7 6 IN_6 7 IN_6 8 IN_5 9 IN_5 10 IN_4 11 IN_4 12 IN_3 13 IN_3 14 IN_2 15 IN_2 16 IN_1 17 IN_1 18 GND Pin Number SENSOR IN 3 IO Terminal Board User Information ...

Page 6: ..._7 6 OUT _6 7 OUT _6 8 OUT _5 9 OUT _5 10 OUT _4 11 OUT _4 12 OUT _3 13 OUT _3 14 OUT _2 15 OUT _2 16 OUT _1 17 OUT _1 18 GND 19 RS 422 485 TX 20 RS 422 485 TX 21 RS 422 RX 22 RS 422 RX Pin Number ALARM OUT 4 Vess A2000 NVR Storage Appliance Promise Technologies ...

Page 7: ...cle Insert a small flat head screwdriver into the slot above the hole you want to connect Hold the screwdriver in place and insert the wire then release the screwdriver See illustration below 5 IO Terminal Board User Information ...

Page 8: ...this example a motion sensing camera is connected Connect the SENSOR_IN on the Vess I O terminal interface with an external camera Alarm Out Red wire in illustration Connect the SENSOR_IN on the Vess I O terminal interface with an external camera Alarm Out Black wire in illustration See Sensor Input Connector on page 3 for pin assignments 6 Vess A2000 NVR Storage Appliance Promise Technologies ...

Page 9: ...enclosure v the sensor status displays 2 The Sensor Status displayed is dependant on the input pair that is used on the Sensor Input interface For example the Input 4 pair IN_4 and IN_4 displays Sensor Status 247 Use the value to calculate which pair is connected to a camera or alarm Use the tables on pages 14 and 15 in FAQ 7 IO Terminal Board User Information ...

Page 10: ...vice Blue wire in illustration Connect the ALARM_OUT on the I O terminal interface to the Input connection on the external alarm device Red wire in illustration Connect the ALARM_GND on the I O terminal interface to the Input connection on the external alarm device Black wire in illustration See Alarm Output Connector on page 4 for pin assignments 8 Vess A2000 NVR Storage Appliance Promise Technol...

Page 11: ...signal to the alarm when the sensor device is triggered follow these steps 1 Open the CLI interface type enclosure a mod s alarmstatus 1 2 To check the Alarm Status type enclosure v Change the Alarm Status to enable or disable the connected external alarm device See FAQ on page 14 for more information 9 IO Terminal Board User Information ...

Page 12: ...e Alarm Device To disable the alarm device 1 Open CLI and type enclosure a mod s alarmstatus 0 2 Type enclosure v and it will displays the alarmstatus 10 Vess A2000 NVR Storage Appliance Promise Technologies ...

Page 13: ...connector four rightmost pins on the alarm output connector RS 232 Port 1 This is used for control line connection to an uninterruptible power supply UPS RS 232 Port 2 Use this to connect to analog cameras via the analog camera input cable Note This connector cannot be used at the same time as the RS 422 485 connector RS 422 RS 485 Use this to connect to analog cameras via the analog camera input ...

Page 14: ...re a mod s uartstaus 0 2 Type enclosure v and it will displays the UartStatus Configure RS 422 485 I O Terminal Board Choosing this option enables the RS 422 485 port on the terminal board and disables the RS 232 port 1 Open CLI and type enclosure a mod s uartstatus 1 2 Type enclosure v and it will displays the UartStatus 12 Vess A2000 NVR Storage Appliance Promise Technologies ...

Page 15: ...Illustrated Connection Vess A2200 Illustrated Connection Vess A2600 13 IO Terminal Board User Information ...

Page 16: ...as no signal input Example 1 Sensor Status is 72 in CLI 26 plus 23 equals 72 SENSOR IN_7 and SENSOR IN_4 have no input signal i e Sensor Status Disable All other SENSOR IN 1 2 3 5 6 8 have input signals i e Sensor Status Enable Example 2 Sensor status is 255 in CLI All SENSOR IN 1 2 3 4 5 6 7 8 have no input signals i e Sensor Status Disable Pin No SENSOR IN Sensor Status Enable Disable 2 IN_8 0 2...

Page 17: ...ARM_OUT 2 3 4 5 6 7 and 8 have signal input ALARM_OUT 20 has no warning Example 1 Alarm Status is 129 in CLI 27 plus 20 equals 129 ALARM_OUT _8 and ALARM_OUT_1 have no warning Example 2 Alarm status is 255 in CLI No warning signal output on all alarms Pin No ALARM OUT Alarm Status Enable Disable 2 OUT_8 0 27 3 OUT_8 4 OUT_7 0 26 5 OUT_7 6 OUT_6 0 25 7 OUT_6 8 OUT_5 0 24 9 OUT_5 10 OUT_4 0 23 11 OU...

Page 18: ......

Reviews: