ProMinent vonTaine 1010 PP Assembly And Operating Instructions Manual Download Page 1

Solenoid-coupled centrifugal pump
vonTaine

®

 1010 PP and PVDF

Assembly and operating instructions

A2924

Insert type and serial no. here: ________________________________________________________________

EN

Original operating instructions (2006/42/EC)

Part no. 987044

Version: BA vT 017 11/19 EN

Please carefully read these operating instructions before use. · Do not discard.

The operator shall be liable for any damage caused by installation or operating errors.

The latest version of the operating instructions are available on our homepage.

Summary of Contents for vonTaine 1010 PP

Page 1: ..._________________________________ EN Original operating instructions 2006 42 EC Part no 987044 Version BA vT 017 11 19 EN Please carefully read these operating instructions before use Do not discard T...

Page 2: ...formation includes detailed descriptions of the haz ardous situation see Chapter 2 1 Labelling of Warning Informa tion on page 7 The following symbols are used to highlight instructions links lists re...

Page 3: ...8 5 1 Preparations for Operation 19 5 2 Start Up 19 5 3 Operation 20 5 4 Decommissioning 20 6 Maintenance Servicing 21 6 1 Preventative maintenance 21 6 2 Dismantling the pump head 23 6 3 Assembling t...

Page 4: ...re the pump is operated A2456 2 5 4 3 1 Fig 1 Basic diagram Main units of the vonTaine pump 1 Terminal box 2 Electrical capacitor 3 Pump housing with pump head 4 Mounting foot 5 Drive housing with dri...

Page 5: ...type vonTaine 1010 PP FKM vonTaine 1010 PVDF FKM vonTaine 1010 PP EPDM vonTaine 1010 PVDF EPDM Max pump capacity 1800 l h Operating range 30 1800 l h Max delivery height 4 5 mWs Maximum system pressu...

Page 6: ...ins frequency in Hertz n Current strength in Amps n Output in Watts n Capacitor capacity in Farad F n Maximum feed rate in l h Qmax n Maximum delivery height in mWs Hmax 1 4 Materials Unit XXXX PP XXX...

Page 7: ...rve only as examples DANGER Nature and source of the danger Consequence Fatal or very serious injuries Measure to be taken to avoid this danger Description of hazard Denotes an immediate threatening d...

Page 8: ...ibly damaging situation If the situation is disregarded the product or an object in its vicinity could be damaged Type of information Hints on use and additional information Source of the information...

Page 9: ...ther authorised distribution partner Trained qualified per sonnel A trained qualified employee is deemed to be a person who is able to assess the tasks assigned to him and recognize possible hazards b...

Page 10: ...eld The pump contains very strong magnets When working on the pump pay particular attention to the danger from magnetic fields These magnetic fields can for example affect pacemakers People affected b...

Page 11: ...2 5 Sound Pressure Level Sound pressure level LpA 70 dB according to EN ISO 20361 At maximum feed rate and maximum back pressure water Sound pressure level Safety 11...

Page 12: ...nsing n Other No dust no direct sunlight 3 1 Transport Only transport the sensor in its original packaging and in compli ance with the permissible environmental conditions No further special condition...

Page 13: ...ssible consequence Fatal or very serious inju ries Please ensure when handling hazardous sub stances that you have read the latest safety data sheets provided by the manufacture of the haz ardous subs...

Page 14: ...s The weight of the lines may not exert a load on the pump housing 2 Lead the suction and discharge lines without tension to the pump housing It is the duty of the operator of the pump to ensure that...

Page 15: ...oke valve into the discharge line to reg ulate the delivery flow 4 3 Electrical connection n Protect the motor with a motor protection switch n Switch off the supply voltage a minimum of 5 minutes bef...

Page 16: ...6 Cover of the terminal box with connection diagram 1 Cover of the terminal box with connection dia gram 2 Terminal box 3 Electrical capacitor 4 Cable opening with cable dummy Arrangement Installation...

Page 17: ...ram in Fig 7 NOTICE Damage is possible to the pump Pump running dry Only check the direction of rota tion with liquid in the pump 2 Pay attention to the directional arrows on the pump see Check the di...

Page 18: ...ularly and replace if neces sary as the hazard potential of a substance can be re evaluated at any time based on new findings The system operator is responsible for ensuring that these safety data she...

Page 19: ...p housing and the suction line noting the material safety data sheet for the feed chem ical 2 Check that all connector threads are tight 3 Open all suction side shut off valves 5 2 Start Up NOTICE Con...

Page 20: ...again check whether the pump impeller is rotating smoothly 2 Check whether the suction line and the pump housing are filled with medium 3 Switch on the motor again If the pump pumps briefly and then...

Page 21: ...based on new findings The system operator is responsible for ensuring that these safety data sheets are available and that they are kept up to date as well as for producing an associated hazard assess...

Page 22: ...for deposits at regular intervals Interval once a year In the event of dirt sludge like and crystallising media check the pump at shorter intervals if required and clean when necessary 3 Check the sta...

Page 23: ...AF10 2 Carefully pull the pump head assembly 001 from the housing 113 Tool lever 3 Remove the pump housing 101 from the centring shaft 211 Remove the impeller magnet 847 1 with the impeller 230 out of...

Page 24: ...tling the pump head 5 Loosen the impeller 230 from the impeller magnet 847 1 Tool lever 6 Loosen the thrust ring 314 2 from the impeller 230 Tool section of pipe with an internal of 80 mm Punch 6 mm M...

Page 25: ...on the centring shaft 211 A2927 I II Fig 12 Assembling the pump head 1 Fit the slide bearing 310 pay attention to the anti turn locking device Tool manual toggle press 2 Press the impeller 230 onto th...

Page 26: ...e you restart The motor is becoming too hot Fan and fan cowling are dirty Clean the fan and fan cowling The pump is running but not pumping Air in the lines Bleed vent The pump is making loud flowing...

Page 27: ...sheets are available and that they are kept up to date as well as for producing an associated hazard assessment for the worksta tions affected NOTICE The used part can only be accepted with a com plet...

Page 28: ...medium 80 C 95 C 80 C 95 C Maximum viscosity 20 mPas 20 mPas 20 mPas 20 mPas Max ambient tem perature 40 C 40 C 40 C 40 C Max density of the medium 1 6 2 0 kg dm 1 6 2 0 kg dm 1 6 2 0 kg dm 1 6 2 0 kg...

Page 29: ...view drawing 10 2 Parts list for vonTaine 1010 PP FPM Pos Qty Part no Designation Material 101 1 PUMA 14 0180 020 Pump housing without thrust ring Polypropylene 113 1 PUMA 00 0370 020 Housing 30 mm A...

Page 30: ...130x3 FKM 412 2 1 PUMA 12 0150 015 O ring 32x3 5 FKM 554 2 6 PUMA 00 0090 150 Washer 6 4 DIN125 A2 800 1 PUMA 00 0370 001 Motor 370 W 230 400 V 3 phase AC 847 1 1 PUMA 14 0180 131 Internal magnet 9 m...

Page 31: ...6 4 DIN125 A2 800 1 PUMA 00 0370 001 Motor 370 W 230 400 V 3 phase AC 847 1 1 PUMA 14 0180 156 Internal magnet 90mm PVDF 847 2 1 PUMA 12 0150 076 Drive magnet 30 18S W D 14 mm 900 4 PUMA 00 0090 110 C...

Page 32: ...gonal screw M6x55 DIN931 A2 904 1 PUMA 05 0050 00 7 Set screw M6x10 DIN914 45H 940 1 PUMA 00 0370 02 9 Feather key 5x25x5 10 5 Parts list for vonTaine 1010 PVDF EPDM Pos Qty Part no Designation Materi...

Page 33: ...4 DIN125 A2 800 1 PUMA 00 0370 00 1 Motor 370 W 230 400 V 3 phase AC 847 1 1 PUMA 14 0180 15 6 Internal magnet 90 mm PVDF 847 2 1 PUMA 12 0150 07 6 Drive magnet 30 18S W D 14 mm 900 4 PUMA 00 0090 11...

Page 34: ...11 Appendix 11 1 Dimensional drawing of vonTaine 1010 PP and PVDF A2929 Fig 14 Dimensional drawing of vonTaine 1010 PP and PVDF Appendix 34...

Page 35: ...11 2 Characteristic curves A2930 Fig 15 Characteristic curves Delivery height mWs motor capacity watts efficiency all in relation to pump capacity l h Appendix 35...

Page 36: ...11 3 Motor data sheet A2932 Fig 16 Motor data sheet Appendix 36...

Page 37: ...the version distributed by us Any modification to the product not approved by us will invalidate this declaration Tab 2 Extract from the EC Declaration of Conformity Designation of the product Centri...

Page 38: ...anner box wrench 25 L Labels 7 Links to elements or sections of these instruc tions or other applicable documents 2 M Magnetic field 10 Material version 5 Maximum air humidity 12 More symbols 2 N Non...

Page 39: ...39...

Page 40: ...987044 1 en_GB 2019 ProMinent GmbH Im Schuhmachergewann 5 11 69123 Heidelberg Germany Telephone 49 6221 842 0 Fax 49 6221 842 419 Email info prominent com Internet www prominent com...