![ProMinent Ultromat ULFa 1000 Assembly And Operating Instructions Manual Download Page 15](http://html1.mh-extra.com/html/prominent/ultromat-ulfa-1000/ultromat-ulfa-1000_assembly-and-operating-instructions-manual_1616951015.webp)
3
Transporting and storing the system
User qualification: trained user, see
Chapter 2.3 ‘Users' qualifications’
WARNING!
High system weight
Possible consequence: Death or severe injuries, if the floor
cannot support the system and breaks.
Measure: Ensure that the floor of the installation site can
support the weight of both the empty and full system.
WARNING!
Never stand under suspended loads.
Possible consequence: Fatal or very serious injuries
–
It is prohibited to walk under or stand underneath sus‐
pended loads
–
When lifting and transporting the Ultromat ensure it
cannot slip or topple
–
Use suitable approved lifting tackle. Observe the infor‐
mation given in the lifting equipment data sheets.
–
Ultromat
®
systems of type 4000 and 8000 may only be
lifted with a traverse if they are fitted with lifting lugs. The
length of the traverse must be at least 10 - 20 cm longer
than the storage tank
CAUTION!
Possibility of damage to the system during transport
Improper transport can result in system damage.
–
Only move the Ultromat
®
system when empty
–
The storage tank wall must not be subjected to point
loading
–
Avoid heavy vibration and impact loads
–
Only move the system with suitable hoisting and lifting
equipment
–
When using forklift trucks, use long forks, which extend
across the entire depth of the storage tank
–
If a crane is used, attach the slings, even if lifting lugs
are fitted, such that shear forces are avoided
Permissible ambient temperature: -5 °C to +50 °C.
Humidity: None. Rain and condensation not permitted.
Other: No dust, no direct sunlight.
Ambient conditions for storage and trans‐
port
Transporting and storing the system
15