Motor data sheets, special motors, special motor flanges,
external fan, temperature monitoring
–
Motor data sheets can be requested for more informa‐
tion.
–
For motors other than those with identity code specifica‐
tions "S", "M" or "N": Pay special attention to the oper‐
ating instructions for the motors.
–
Special motors or special motor flanges are possible on
request.
13.7 Stroke sensor "Sigma"
Install the sensor according to the chapter "Installation, elec‐
trical".
For more information, see "Pacing relay" in the "Relay" chapter.
5–25 V DC, in accordance with Namur or DIN 60947-5-6, potential-free
design.
Data
Value Unit
Nominal voltage *
8 VDC
Power consumption - active surface
uncovered
> 3 mA
Power consumption - active surface cov‐
ered
< 1 mA
Rated switching distance
1.5 mm
* Ri ~ 1 kΩ
Cable colour
Polarity
blue
-
brown
+
13.8 Relay
The electrical data for the relay are contained in the chapter
"Installation, electrical".
a) Pacing relay (stroke sensor with ...)
(Identity code specification "Stroke
sensor": 2)
b) Namur sensor (identity code specifica‐
tion "Stroke sensor": 3)
Technical data
43