7.2.1.1.2
Fault indicating and pacing relay option
The first switch is a relay. The pacing output is electrically-isolated by
means of an optocoupler with a semiconductor switch.
If another switching function is required, the pump can be reprogrammed
in the
‘Relay’
menu.
The relay can be retrofitted and is operational once it has been plugged
into the relay board.
Data
Value Unit
Maximum contact load at 24 V and 50/60
Hz:
100 mA
Minimum mechanical service life:
200,000 switching
operations
Data
Value Unit
Residual voltage max. at I
off max
= 1 µA
0.4 V
Maximum current
100 mA
Maximum voltage
24 VDC
Closing time
100 ms
Pin assignment
To pin
VDE cable
Contact
Relay
1
yellow
NC (normally closed) or
NO (normally open)
Fault indi‐
cating relay
4
green
C (common)
Fault indi‐
cating relay
3
white
NC (normally closed) or
NO (normally open)
Pacing relay
2
brown
C (common)
Pacing relay
2
3
1
4
P_SI_0111_SW
Fig. 24: Pump assignment
Fault indicating relay (24 V)
Pacing relay
Fault indicating and pacing relay option
P_SI_0044
Fig. 25: Cable assignment
Installation
34