16
Technical data
16.1 Performance data
Type
Minimum pump capacity at maximum
back pressure
Max‐
imum
stroke
rate
Suction
lift
Permis‐
sible pri‐
ming pres‐
sure,
suction
side
Connector
size
bar
psi
l/h
gph
Strokes/
min
ml/stroke
m WS
bar
R"-DN
120145 PVT
10
145
182
48
90
33.7
5
2
1 1/2" -
DN25
120145 SST
12
174
182
48
90
33.7
5
2
1 1/2" -
DN25
120190 PVT
10
145
243
64
120
33.7
5
2
1 1/2" -
DN25
120190 SST
12
174
243
64
120
33.7
5
2
1 1/2" -
DN25
120270 PVT
10
145
365
96
180
33.8
5
2
1 1/2" -
DN25
120270 SST
12
174
365
96
180
33.8
5
2
1 1/2" -
DN25
070410 PPT,
PCT, PVT
7
102
500
132
90
95.1
4
1
2" - DN32
070410 SST
7
102
500
132
90
95.1
4
1
2" - DN32
070580 PPT,
PCT, PVT
7
102
670
176
120
95.1
4
1
2" - DN32
070580 SST
7
102
670
176
120
95.1
4
1
2" - DN32
040830 PPT,
PCT, PVT
4
58
1040
274
180
95.1
3
1
2" - DN32
040830 SST
4
58
1040
274
180
95.1
3
1
2" - DN32
All figures refer to water at 20 °C.
The suction lift applies to filled suction line and filled liquid end - when
installed correctly.
Data
Value Unit
Reproducibility
±2 % *
* - when installed correctly, under constant conditions, at least 30%
stroke length and water at 20 °C
S3Cb
Precision
Technical data
86
Summary of Contents for S3Cb
Page 107: ...PTFE FDA No 21 CFR 177 1550 PVDF FDA No 21 CFR 177 2510 Wear parts for S3Cb 107 ...