![ProMinent gamma/ X Operating Instructions Manual Download Page 79](http://html1.mh-extra.com/html/prominent/gamma-x/gamma-x_operating-instructions-manual_1616937079.webp)
17.2 Accuracy
17.2.1 Standard Liquid End
Data
Value Unit
Capacity range of the series
-5 ... +10 % *
Reproducibility
±2 % **
* - at max. stroke length and max. operating pressure for all material
versions
** - at constant conditions and min. 30 % stroke length
17.2.2 Self-Bleeding Liquid End
As the self-bleeding liquid end is used with outgassing media and when
operating with air bubbles, no dosing accuracy or reproducibility can be
provided.
The recommended minimum stroke length with self-bleeding dosing
pumps is 50 %.
17.3 Viscosity
The liquid ends are suitable for the following viscosity ranges:
Design
Range
Unit
Standard
0 ... 200
mPas
With valve springs
200 ... 500
mPas
With HV head
500 ... 3000*
mPas
Self-bleeding (SEK)
0 ... 50
mPas
* Even significantly higher with corrected adjusted installation. Contact
Technical; Support in Heidelberg.
Technical Data