9
Start Up
The DulcoFlow
®
can be used to aid
troubleshooting or commissioning of
different output signals – refer to the
"Installation" - "Main Menu Settings" -
"Counter Output Menu" or "Current
Output Menu" chapters.
1.
Connect the device hydraulically with
the overall installation.
2.
Connect the signal cables for the
device.
3.
Connect the device to the supply
voltage.
4.
If necessary set:
n
the
‘language’ - see
n
the
‘pump type’ - see
n
the measured variable to "mass"
and density of the feed chemical -
see
n
the units - see
n
the current output - see
8.4.2.3 ‘“Current output” menu’
n
8.4.2.2 ‘“Counter output” menu’
5.
Allow the metering pump to prime and
bleed the installation - simultaneously
press both
[arrow keys] on the pump's
control unit.
6.
On the unit, press
[P] to acknowledge
the
‘gas bubbles’ fault.
7.
Allow the metering pump to run.
8.
If used as a dosing monitor: Check
whether the stroke feedback to the
metering pump is plausible.
If this is not the case, proceed in accord‐
ance with the handling instructions,
which can be found after the tips.
9.
Check whether the displayed values are
plausible.
Start Up