8.4.3.2.1 By input
B0244
P
P
P
calibration
quantity
corr. factor
101.23 %
quantity
corr. factor
calibration
stroke feedback
If the new correction factor is know in %, it can be entered directly here.
It is obtained by dividing a value you have measured yourself by the displayed value and multiplying
the result by 100.
1.
Follow the
‘calibration
è
stroke feedback’ menu path.
2.
Use the
[arrow keys] to move to the ‘calibration quantity’ menu item and press [P] twice.
3.
Use the
[arrow keys] to enter the ‘corr. factor’ and press [P].
ð
The continuous display appears again.
8.4.3.2.2 By measured values
CAUTION!
Danger with dangerous feed chemicals
Provided the following handling instruc‐
tions are followed, contact with the feed
chemical is possible.
–
If the feed chemical is dangerous,
take appropriate safety precau‐
tions when carrying out the fol‐
lowing handling instructions.
–
Observe the feed chemical safety
data sheet.
Depending on the set measured variable, a cal‐
ibration menu appears for:
n
Volume
n
Mass
Set up
49