11.7.5 Replace the O-rings on the Anode Pipe
A2001
5.
6.
1.
2.
3.
4.
Fig. 79: O-rings on the anode pipe
1.
Open the vacuum ejector coupling (6).
2.
Replace the O-rings.
3.
Open the coupling (5) on the upper side of the anode pipe.
4.
Replace the O-rings.
5.
Replace the O-ring on the lower measuring pipe connector
(3).
6.
Replace the O-ring on the lower anode pipe connector (2).
7.
Replace the O-ring on the stop pipe (4).
8.
Open the coupling (1) on the upper side of the measuring
pipe.
9.
Replace the O-ring.
10. Check the upper stop for oxidation.
11. Replace the upper stop.