11.5.10 Maintenance on the Fan
A1991
1. 2.
3.
4.
5.
Fig. 72: Maintenance on the fan
1.
Loosen the hose clamps (1) on the side of the lye storage
tank.
2.
Loosen the screw on the fan flange.
3.
Remove the connecting section (2).
4.
Remove the fan (3).
5.
Carefully rinse the fan (4) with water
6.
Fit the fan.
7.
Fit the connecting section.
8.
Unscrew the adjustment screw and remove the air flow
sensor (5) out of the supply pipe.
9.
Clean the air flow sensor.
10. Fit the air flow sensor.
11.6 Maintenance on the Membrane Cell
n
User qualification, maintenance: trained user, see
2.2 ‘User qualification’ on page 10
Maintenance on the Air Flow Sensor
Preventative maintenance
94