11.8.7 Replacing the sealing rings on the product suction unit
INFORMATION!: The maintenance package includes two versions
of sealing rings for check valves. This means that there is always a
spare sealing ring and O-ring.
A2005
1.
2.
3.
Fig. 84: Sealing rings on the product suction unit
1.
Dismantle the threaded connector (1) on the check valve.
2.
Replace the O-ring (2).
3.
Dismantle the float (3) from the check valve.
4.
Replace the seal on the float.
5.
Fit the threaded connector (1) into the check valve.
11.9 Maintenance on the Control Cabinet
n
User qualification, maintenance: trained user, see
2.2 ‘User qualification’ on page 10
Preventative maintenance