ProMinent Beta b BT4b 0220 Operating Instructions Manual Download Page 1

Solenoid Metering Pump
Beta

®

 b BT4b and BT5b

Operating instructions

EN

Original operating instructions (2006/42/EC)

Part no. 986356

BA BE 033 08/18 EN

Please carefully read these operating instructions before use. · Do not discard.

The operator shall be liable for any damage caused by installation or operating errors.

The latest version of the operating instructions are available on our homepage.

Summary of Contents for Beta b BT4b 0220

Page 1: ...ctions 2006 42 EC Part no 986356 BA BE 033 08 18 EN Please carefully read these operating instructions before use Do not discard The operator shall be liable for any damage caused by installation or o...

Page 2: ...Information This provides important information relating to the cor rect operation of the unit or is intended to make your work easier Safety Information Safety information is identified by pictograms...

Page 3: ...lation hydraulic 20 8 1 Installing hose lines 21 8 1 1 Installation of metering pumps without bleed valve 21 8 1 2 Installation of metering pumps with bleed valve 23 8 1 3 Installation of metering pum...

Page 4: ...iquid End 54 16 3 Viscosity 54 16 4 Material specifications 55 16 5 Electrical data 55 16 6 Temperatures 57 16 7 Climate 57 16 8 Degree of Protection and Safety Requirements 58 16 9 Compatibility 58 1...

Page 5: ...coated only for PP and NP self bleeding SEK S Diaphragm with additional FPM coating for media containing silicate F FDA compliant Dosing head design 0 without bleed valve without valve spring only for...

Page 6: ...lt indicating relay NC change over relay 3 fault indicating relay NO change over relay 4 as 1 pacing relay ONE each 5 as 3 pacing relay ONE each Accessories 0 no accessories 1 with foot and injection...

Page 7: ...ep down compared with the pre ceding model This enables it to adapt more precisely to external signal generators The result is the simpler and more precise adjustment of chemical consumption to the ac...

Page 8: ...ing instructions n Observe the general limitations with regard to viscosity limits chem ical resistance and density see also ProMinent resistance list in the Product Catalogue or at www prominent com...

Page 9: ...g safety glasses safety gloves Adhere to the material safety data sheet for the feed chemical Drain and flush the liquid end before working on the pump WARNING Fire danger When pumping inflammable me...

Page 10: ...damage the parts of the pump that come into contact with the chemical Take into account the resistance of the wetted mate rials and the ProMinent Resistance List when selecting the feed chemical see t...

Page 11: ...a thorough knowledge of metering pumps Hydraulic installation Technical personnel service Installation electrical Electrical technician Operation Instructed person Maintenance repair Technical person...

Page 12: ...instructed and if required trained in the tasks assigned to him her and possible dan gers that could result from improper behaviour as well as having been instructed in the required protective equipm...

Page 13: ...ound on our homepage CAUTION Danger of material damage The device can be damaged by incorrect or improper storage or transportation The unit should only be stored or transported in a well packaged sta...

Page 14: ...P_BE_0013_SW Fig 2 Complete overview 1 Control unit 2 Drive unit 3 Liquid end a b c d e f P_BE_0008_SW Fig 3 Overview of liquid end PV a Discharge valve b Backplate c Dosing head d Bleed valve e Bypa...

Page 15: ...at the external control terminal In External Analogue operating mode the stroke rate can be controlled by an mA signal via the pulse control switch To do so the multifunctional switch has to be turne...

Page 16: ...if the pump is ready for operation and there are no fault or warning alerts It goes out quickly as soon as the pump has performed a stroke 5 2 5 External control terminal The external control termina...

Page 17: ...ype 30 100 Recommended stroke length SEK type 50 100 The stroke rate can be set within a range of 10 100 using the multi functional switch 6 4 Self Bleeding Self bleeding liquid ends SEK types are cap...

Page 18: ...via a knock out opening in the pump foot refer to Retrofitting relays 6 8 Hierarchy of Operating Modes Functions and Fault Statuses The different operating modes functions and fault statuses have a di...

Page 19: ...can arise from a poorly accessible pump due to incorrect operation and poor maintenance Ensure that the pump is accessible at all times Adhere to the maintenance intervals Capacity too low The liquid...

Page 20: ...that you have failed to do so turn the multifunctional switch to Stop if fitted or press an On Off switch or Emergency Stop switch on site CAUTION Warning of feed chemical spraying around Feed chemica...

Page 21: ...all hydraulic components please refer to the product specific operating instructions and system documentation Never allow the metering pump to run against a closed shut off device Install a relief val...

Page 22: ...4 and widen if necessary Ensure that the O ring and or the flat seal 5 is sitting properly in the valve 6 Never re use used PTFE seals An installation sealed in this way is not watertight This type of...

Page 23: ...e event that hose lines are installed incorrectly on stainless steel valves Only use PE or PTFE hose lines In addition insert a stainless steel support insert into the hose line 8 1 2 Installation of...

Page 24: ...bleeding function However operation with priming pressure in the return line and the suction end at atmospheric pres sure is possible A return line is also connected in addition to the suction and di...

Page 25: ...rupture if the maximum per missible operating pressure is exceeded Never allow the metering pump to run against a closed shut off device With metering pumps without integral relief valve Install a rel...

Page 26: ...stallation 1 Main line 2 Storage tank Symbol Explanation Symbol Explanation Metering pump Foot valve with filter meshes Injection valve Level switch Multifunctional valve Manometer Legend for hydrauli...

Page 27: ...e emergency cut off man agement of the system and inform personnel of the isolating option WARNING Danger of electric shock A mains voltage may exist inside the pump housing If the pump housing has be...

Page 28: ...power supply Avoid the escape of feed chemical If you have not done so immediately press STOP START or disconnect the pump from the mains voltage e g using an Emergency Stop switch Refer to the mater...

Page 29: ...periodically checks the supply voltage wait time after stroke abort 10 min The pump will recommence operation if the supply voltage is sufficient The pump s electrical system will shut down com plete...

Page 30: ...rokes min With current signals above 23 mA the red fault indicator lights up the pump stops and any fault indicating relay fitted switches a fault is pending Only with 4 20 mA With current signals bel...

Page 31: ...itch terminal There is a connecting option for a 2 stage level switch with pre warning and limit stop Electrical interface Data Value Unit Voltage with open contacts 5 V Input resistance 10 k Control...

Page 32: ...is a fault with the pump and for the Liquid level low 1st stage warning message and Liquid level low 2nd stage fault message A cut off relay works when there are fault alerts from the pump and in the...

Page 33: ...for fault indicating relays Data Value Unit Maximum contact load at 24 V and 50 60 Hz 8 A Minimum mechanical lifespan 200 000 switching operations for semiconductor switch pacing relay Data Value Uni...

Page 34: ...us feed chemicals Contact with the feed chemical is possible provided the following handling instructions are adhered to If the feed chemical is dangerous take appropriate safety precautions when carr...

Page 35: ...ether the bleed valve is closed 6 Start up the relief valve in the system in line with its operating instructions 7 Start up the system 8 After 24 hours of operation Tighten the screws on the dosing h...

Page 36: ...ing metering pumps SEK type The return line is connected to the vertical valve on the top of the liquid end It is labelled with a red sleeve ex works The discharge line is connected to the horizontal...

Page 37: ...xist inside the pump housing If the pump housing has been damaged you must disconnect it from the mains immediately It may only be returned to service after an authorised repair 11 1 Manual Personnel...

Page 38: ...ting mode stroke rate settings In the standard version the Auxiliary frequency function is programmed to 100 stroke rate 11 1 3 External contact In the Extern Contact operating mode either a series of...

Page 39: ...Explanation of the stepped down values Settable values Incoming contacts Strokes performed such as External Ana logue such as External Ana logue such as External Ana logue 01 16 16 1 01 32 32 1 0 20 m...

Page 40: ...when pumping Only use original spare parts Use the correct spare parts kits In the event of doubt refer to the exploded views and ordering information in the appendix Interval Maintenance work Personn...

Page 41: ...the bleed valve is tight n Check the discharge and bypass line for kinks n Check that the bleed valve is operating correctly Under normal loading approx 30 of continuous operation Under heavy loading...

Page 42: ...ons in the Storage Transport and Unpacking chapter prior to shipping the pump WARNING Contact with the feed chemical Parts that come into contact with the feed chemical are exposed and touched during...

Page 43: ...ts are identical here n There is an additional spacer between the valve inserts n There is a shaped seal in the dosing head instead of an O ring n The flow direction of the suction connector is the op...

Page 44: ...Please note however that n The flow direction of the suction connector is the opposite to that of the pressure connector Repairs 44...

Page 45: ...ve the screws 1 7 Loosen the dosing head 2 and the backplate 4 from the pump housing 6 but only loosen 8 Hold the pump housing 6 with one hand and clamp the diaphragm 3 with the other hand between the...

Page 46: ...3 in a clock wise direction until it is sitting tightly the twisting resistance of the return spring can be felt 20 Set the stroke length to 100 21 Place the dosing head 2 with the screws 1 onto the...

Page 47: ...1 2 3 4 5 6 P_BE_0018_SW Fig 18 Partially exploded view of liquid end Repairs 47...

Page 48: ...ts if they are manipulated or opened due to pressure in the liquid end and adjacent parts of the system Disconnect the pump from the mains power supply and ensure that it cannot be switched on again b...

Page 49: ...storage tank Instructed personnel The pump is in External Analogue oper ating mode and the control current has risen above 23 mA fault signal Clear the cause of the fault on the pump The pump is in Ex...

Page 50: ...ty gloves Adhere to the material safety data sheet for the feed chemical Drain and flush the liquid end before working on the pump WARNING Fire hazard with flammable media Only with flammable media Th...

Page 51: ...ents in the pump which can have a toxic effect on the environment Note the pertinent regulations currently applicable in your country In accordance with the European Directive 2012 19 EU on waste elec...

Page 52: ...0 24 3 5 3 1 0 29 6x4 6 0 2 5 5 5 0402 4 2 8 0 26 2 0 3 6 0 36 6x4 6 0 2 5 5 5 1604 16 3 6 0 33 8 0 4 3 0 40 6x4 5 0 3 0 3 1004 10 3 9 0 36 5 0 4 7 0 44 6x4 5 0 3 0 3 0704 7 4 2 0 39 3 5 5 1 0 47 6x4...

Page 53: ...4 6 0 3 0 0 5 0404 4 3 9 0 36 2 0 4 2 0 39 6x4 6 0 3 0 0 5 0708 7 6 60 0 61 3 5 7 50 0 69 8x5 6 0 2 0 0 5 0408 4 7 5 0 64 2 0 8 1 0 77 8x5 6 0 2 0 0 5 0413 4 10 8 1 0 2 0 12 6 1 17 8x5 6 0 2 5 0 5 022...

Page 54: ...HV have a 10 20 lower capacity and are not self priming Connector G 3 4 DN 10 with hose nozzle d16 DN10 16 2 Accuracy 16 2 1 Standard Liquid End Data Value Unit Capacity range of the series 5 10 Repr...

Page 55: ...PE and NPB with a valve spring made of Hastelloy C PVDF valve insert Dia phragm with a PTFE coating FPM fluorine rubber All wetted materials in the design with FDA certified seals comply with the foll...

Page 56: ...20 3 1001 8 3 1004 12 7 0713 21 2 0701 7 5 0704 11 1 0420 21 2 0401 6 9 0404 9 5 0232 24 9 2002 13 5 0708 16 5 Parameter Beta b BT4b Nominal power approx 17 4 W Nominal current averaged at 180 H min 3...

Page 57: ...at max operating pressure dependent on the ambient tem perature and the feed chemical temperature Tab 9 Minimum temperature liquid end Material version Value Unit All 10 C Tab 10 Maximum temperature...

Page 58: ...switch 2 stage gamma Vario Beta n Dosing line cross sections n Standard gamma connector kit n Chemical feed container n Overall height distance between the suction and discharge con nector n Same use...

Page 59: ...10 85 81 100 131 5 148 6 80 95 101 41 36 148 153 P_BE_0019_SW Fig 19 Dimensional drawing Beta b BT4b BT5b material version PP dimensions in mm 1000 1604 0708 0220 1008 0420 0232 E 19 5 7 14 1 5 F 179...

Page 60: ...0232 A 80 80 80 80 80 B 92 92 102 102 102 C 95 95 101 101 101 D 148 148 153 153 153 E 19 7 2 24 6 14 3 2 F 172 182 8 178 4 188 198 8 G 131 5 131 5 148 6 148 6 148 6 H 81 81 100 100 100 I 10 10 15 15...

Page 61: ...ions in mm 1601 0401 1602 0404 0708 0413 0220 1008 0713 0420 A 80 80 80 B 92 92 102 C 95 95 101 D 148 148 153 E 19 1 7 5 13 6 F 170 4 182 4 188 4 G 131 5 131 5 148 6 H 81 81 100 I 10 10 15 J 41 41 36...

Page 62: ...0 0402 1604 0404 0708 0220 1008 0420 0232 A 80 80 80 80 B 92 92 102 102 C 95 95 101 101 D 148 148 153 153 E 19 8 1 14 1 3 2 F 179 185 5 191 5 199 G 131 5 131 5 148 5 148 5 H 81 81 100 100 I 10 10 15 1...

Page 63: ...77 75 5 78 5 L 94 95 95 94 96 5 M 70 80 85 85 85 K L 81 85 131 5 135 5 41 36 80 92 102 95 101 148 153 M E F 10 15 P_BE_0024_SW Fig 24 Dimensional drawing Beta b BT4b BT5b material version TT dimensio...

Page 64: ...wing Beta b BT4b BT5b material version SS dimensions in mm 1000 1601 1602 1604 0708 0220 2504 1008 0420 0232 E 33 2 24 4 7 8 31 7 1 8 8 F 156 9 165 6 197 3 170 4 203 3 210 K 78 75 82 72 77 78 L 89 87...

Page 65: ...2 4 6 8 11 13 16 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 20 30 40 50 60 70 80 90 100 180 min 1 90 min 1 72 min 1 54 min 1 36 min 1 18 min 1 162 min 1 144 min 1 126 min 1 108 min 1 100 f 90 80 70 6...

Page 66: ...2 0 4 0 6 0 8 1 1 2 1 4 p bar k B 1 2 3 5 4 6 7 0 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 0 10 20 30 40 50 60 70 80 90 100 180 min 1 90 min 1 72 min 1 54 min 1 36 min 1 18 min 1 162 min 1 144 min 1 126 min 1 10...

Page 67: ...l h BT4b 0402 s A 0 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 p bar k B 1 2 4 5 6 8 10 0 0 2 0 4 0 6 0 8 1 1 2 3 5 7 p bar k B 1 2 4 6 0 0 2 0 4 0 6 0 8 1 1 2 1 2 3 4 p bar k B 0 0 4 0 8 1 2 1 6 2 0 2 4 2 8 3 2 0...

Page 68: ...10 0 10 20 30 40 50 60 70 80 90 100 180 min 1 90 min 1 72 min 1 54 min 1 36 min 1 18 min 1 162 min 1 144 min 1 126 min 1 108 min 1 f C l h BT4b 0408 s A 0 0 2 0 4 0 6 0 8 1 1 2 1 2 3 4 p bar k B 100 9...

Page 69: ...A B 0 1 2 3 4 5 0 10 20 30 40 50 60 70 80 90 100 180 min 1 90 min 1 72 min 1 54 min 1 36 min 1 18 min 1 162 min 1 144 min 1 126 min 1 108 min 1 100 f 90 80 70 60 50 40 30 20 10 C l h BT5b 2504 s p ba...

Page 70: ...5 10 15 20 25 0 10 20 30 40 50 60 70 80 90 100 0 0 2 0 4 0 6 0 8 1 1 2 1 1 5 4 180 min 1 90 min 1 72 min 1 54 min 1 36 min 1 18 min 1 162 min 1 144 min 1 126 min 1 108 min 1 100 f 90 80 70 60 50 40 30...

Page 71: ...19 Exploded drawings and ordering information 19 1 Exploded drawings 1 5 1 8 6 P_BE_0038_SW Fig 32 Liquid end Beta b 1000 1604 PP_2 Exploded drawings and ordering information 71...

Page 72: ...02066 1035318 Spare parts kit 1001645 1001653 1023108 Diaphragm 1000245 1000245 1000245 PPE2 PPB2 PPT2 Liquid end 1002059 1002067 1035319 Spare parts kit 1001646 1001654 1023109 Diaphragm 1000246 1000...

Page 73: ...1 8 6 5 1 P_BE_0039_SW Fig 33 Liquid end Beta b 0708 1008 0220 0420 PP_2 Exploded drawings and ordering information 73...

Page 74: ...111 Diaphragm 1000248 1000248 1000248 PPE2 PPB2 PPT2 Liquid end 1002062 1002070 1035322 Spare parts kit 1001649 1001657 1023112 Diaphragm 1000249 1000249 1000249 PPE2 PPB2 PPT2 Liquid end 1002063 1002...

Page 75: ...1 5 1 8 6 P_BE_0034_SW Fig 34 Liquid end Beta b 0232 PP_0 Exploded drawings and ordering information 75...

Page 76: ...ription 1 Connector kit 5 Discharge valve 6 Diaphragm 8 Suction valve PPE0 PPB0 PPT0 Liquid end 1002064 1002072 1035324 Spare parts kit 1001651 1001659 1023124 Diaphragm 1000251 1000251 1000251 Liquid...

Page 77: ...1 5 1 8 6 P_BE_0035_SW Fig 35 Liquid end Beta b 1000 1604 NP_0 and NP_2 Exploded drawings and ordering information 77...

Page 78: ...lve _0 1002074 1002085 1034569 Spare parts kit 1001714 1001722 1023108 Diaphragm 1000245 1000245 1000245 NPE_ NPB_ NPT_ Liquid end with bleed valve_2 1002195 1002203 1034562 Liquid end without bleed v...

Page 79: ...1 5 1 8 6 P_BE_0036_SW Fig 36 Liquid end Beta b 0708 1008 0220 0420 NP_0 and NP_2 Exploded drawings and ordering information 79...

Page 80: ...48 1000248 NPE_ NPB_ NPT_ Liquid end with bleed valve _2 1002198 1002206 1034565 Liquid end without bleed valve _0 1002078 1002089 1034578 Spare parts kit 1001718 1001726 1023112 Diaphragm 1000249 100...

Page 81: ...1 5 1 8 6 P_BE_0037_SW Fig 37 Liquid end Beta b 0232 NP_0 and NP_2 Exploded drawings and ordering information 81...

Page 82: ...valve 6 Diaphragm 8 Suction valve NPE_ NPB_ NPT_ Liquid end with bleed valve _2 1002200 1002208 1034567 Liquid end without bleed valve _0 1002080 1002091 1034580 Spare parts kit 1001720 1001728 102312...

Page 83: ...1 1 5 8 6 P_BE_0032_SW Fig 38 Liquid end Beta b 1000 1604 PV_2 Exploded drawings and ordering information 83...

Page 84: ...s kit 1023107 Diaphragm 1000244 PVT2 Liquid end 1023135 Spare parts kit 1023108 Diaphragm 1000245 PVT2 Liquid end 1023136 Spare parts kit 1023109 Diaphragm 1000246 PVT2 Liquid end 1035298 Spare parts...

Page 85: ...1 8 6 1 5 P_BE_0033_SW Fig 39 Liquid end Beta b 0708 1008 0220 0420 PV_2 Exploded drawings and ordering information 85...

Page 86: ...n valve PVT2 Liquid end 1023138 Spare parts kit 1023111 Diaphragm 1000248 PVT2 Liquid end 1023139 Spare parts kit 1023112 Diaphragm 1000249 PVT2 Liquid end 1023140 Spare parts kit 1023113 Diaphragm 10...

Page 87: ...1 5 1 8 6 P_BE_0034_SW Fig 40 Liquid end Beta b 0232 PV_0 Exploded drawings and ordering information 87...

Page 88: ...end Beta b 0232 PV_0 Pos Description 1 Connector kit 5 Discharge valve 6 Diaphragm 8 Suction valve PV_0 Liquid end 1023141 Spare parts kit 1023124 Diaphragm 1000251 Liquid end Beta b 0232 Exploded dra...

Page 89: ...1 1 6 P_BE_0047_SW P_BE_0047_SW Fig 41 Liquid end Beta b 1604 0220 0420 PV_4 Exploded drawings and ordering information 89...

Page 90: ...42 Diaphragm 1034612 PV_4 Liquid end 1018073 Spare parts kit 1019067 Diaphragm 1000248 PV_4 Liquid end 1018084 Spare parts kit 1019069 Diaphragm 1000249 PV_4 Liquid end 1018085 Spare parts kit 1019070...

Page 91: ...1 1 5 8 6 P_BE_0029_SW Fig 42 Liquid end Beta b 1000 1604 TTT0 Exploded drawings and ordering information 91...

Page 92: ...s kit 1001737 Diaphragm 1000244 TTT0 Liquid end 1002346 Spare parts kit 1001738 Diaphragm 1000245 TTT0 Liquid end 1002347 Spare parts kit 1001739 Diaphragm 1000246 TTT0 Liquid end 1034582 Spare parts...

Page 93: ...1 1 5 8 6 P_BE_0030_SW Fig 43 Liquid end Beta b 0708 1008 0220 0420 TTT0 Exploded drawings and ordering information 93...

Page 94: ...TTT0 Liquid end 1002349 Spare parts kit 1001741 Diaphragm 1000248 TTT0 Liquid end 1002350 Spare parts kit 1001742 Diaphragm 1000249 TTT0 Liquid end 1002351 Spare parts kit 1001754 Diaphragm 1000250 Li...

Page 95: ...1 1 5 8 6 P_BE_0031_SW Fig 44 Liquid end Beta b 0232 TTT0 Exploded drawings and ordering information 95...

Page 96: ...end Beta b 0232 TTT0 Pos Description 1 Connector kit 5 Discharge valve 6 Diaphragm 8 Suction valve TTT0 Liquid end 1002352 Spare parts kit 1001755 Diaphragm 1000251 Liquid end Beta b 0232 Exploded dra...

Page 97: ...1 8 6 5 1 P_BE_0026_SW Fig 45 Liquid end Beta b 1000 1604 SS_0 Exploded drawings and ordering information 97...

Page 98: ...s kit 1001729 Diaphragm 1000244 SST0 Liquid end 1002338 Spare parts kit 1001730 Diaphragm 1000245 SST0 Liquid end 1002339 Spare parts kit 1001731 Diaphragm 1000246 SST0 Liquid end 1034581 Spare parts...

Page 99: ...1 1 5 8 6 P_BE_0027_SW Fig 46 Liquid end Beta b 0708 1008 0220 0420 SS_0 Exploded drawings and ordering information 99...

Page 100: ...n valve SST0 Liquid end 1002341 Spare parts kit 1001733 Diaphragm 1000248 SST0 Liquid end 1002342 Spare parts kit 1001734 Diaphragm 1000249 SST0 Liquid end 1002343 Spare parts kit 1001735 Diaphragm 10...

Page 101: ...1 1 5 8 6 P_BE_0028_SW Fig 47 Liquid end Beta b 0232 SS_0 Exploded drawings and ordering information 101...

Page 102: ...end Beta b 0232 SS_0 Pos Description 1 Connector kit 5 Discharge valve 6 Diaphragm 8 Suction valve SST0 Liquid end 1002344 Spare parts kit 1001736 Diaphragm 1000251 Liquid end Beta b 0232 Exploded dra...

Page 103: ...1 5 1 8 6 P_BE_0035_SW Fig 48 Liquid end Beta b 1602 1604 SER self bleeding without bypass NPT7 Exploded drawings and ordering information 103...

Page 104: ...rge valve 6 Diaphragm 8 Suction valve NPT7 Liquid end SER self bleeding without bypass 1075598 Spare parts kit 1047830 Diaphragm 1000246 NPT7 Liquid end SER self bleeding without bypass 1075599 Spare...

Page 105: ...1 5 1 8 6 P_BE_0036_SW Fig 49 Liquid end Beta b 0708 1009 0220 0420 SER self bleeding without bypass NPT7 Exploded drawings and ordering information 105...

Page 106: ...bleeding without bypass 1075600 Spare parts kit 1047832 Diaphragm 1000248 NPT7 Liquid end SER self bleeding without bypass 1075601 Spare parts kit 1047833 Diaphragm 1000249 NPT7 Liquid end SER self bl...

Page 107: ...1 1 5 8 6 P_BE_0032_SW Fig 50 Liquid end Beta b 1602 1604 SER self bleeding without bypass PVT7 Exploded drawings and ordering information 107...

Page 108: ...rge valve 6 Diaphragm 8 Suction valve PVT7 Liquid end SER self bleeding without bypass 1048634 Spare parts kit 1047830 Diaphragm 1000246 PVT7 Liquid end SER self bleeding without bypass 1048635 Spare...

Page 109: ...1 8 6 1 5 P_BE_0033_SW Fig 51 Liquid end Beta b 0708 1008 0220 0420 SER self bleeding without bypass PVT7 Exploded drawings and ordering information 109...

Page 110: ...bleeding without bypass 1048637 Spare parts kit 1047832 Diaphragm 1000248 PVT7 Liquid end SER self bleeding without bypass 1048638 Spare parts kit 1047833 Diaphragm 1000249 PVT7 Liquid end SER self bl...

Page 111: ...1 4 5 8 10 9 6 P_BE_0041_SW Fig 52 Liquid end Beta b 1601 1604 PP_9 and NP_9 Exploded drawings and ordering information 111...

Page 112: ...04 1035302 Tab 32 Liquid ends Type Order no NPE9 1601 1002248 1602 1002249 1604 1035299 NPB9 1601 1002242 1602 1002243 1604 1035300 Spare parts kits for type Material version Order no 1601 PPE 1001756...

Page 113: ...Spare parts kits for type Material version Order no 1602 NPB 1001667 1604 NPB 1035334 Diaphragm for type Order no 1601 1000245 1602 1000246 1604 1034612 Exploded drawings and ordering information 113...

Page 114: ...1 4 5 8 10 9 6 P_BE_0040_SW Fig 53 Liquid end Beta b 0708 1008 0220 0420 PP_9 and NP_9 Exploded drawings and ordering information 114...

Page 115: ...ends Type Order no NPE9 0708 1008 1002251 0413 0713 1002252 0220 0420 1002253 NPB9 0708 1008 1002245 0413 0713 1002246 0220 0420 1002247 Spare parts kits for type Material version Order no 0708 1008 P...

Page 116: ...on Retrofit kit Order no Fault indicating relay for Beta b 1029309 Fault indicating pacing relay for Beta b 1029310 Further information on spare parts accessories and options can be found in n the exp...

Page 117: ...ct from the Declaration of Conformity Designation of the product Metering pump product range Beta 4 and Beta 5 Product type BT4b _ _ _ _ _ _ _ _ _ _ _ U BT5b _ _ _ _ _ _ _ _ _ _ _ U Serial number see...

Page 118: ...not approved by us will invalidate this declara tion Tab 36 Extract from the Declaration of Conformity Designation of the product Metering pump product range Beta 4 and Beta 5 Product type BT4b _ _ _...

Page 119: ...22 Approvals see Chapter Declaration of Conformity It consists of EAC certification with certificate no TC N RU D DE AY14 B 02691 CE EAC Approvals 119...

Page 120: ...og 15 16 31 39 External contact 15 16 30 31 External frequency changeover 18 External frequency changer 16 F Fault 18 Fault indicating and pacing relay option 18 Fault indicating relay 18 32 33 Fault...

Page 121: ...42 Replacing the diaphragm 45 Reproducibility 17 37 54 Retrofit kits 116 Return line 25 Return pipe 21 23 24 S Safety Chapter 8 Safety declaration form 13 Safety Requirements 58 Scope of Delivery 13...

Page 122: ...122...

Page 123: ...123...

Page 124: ...986356 8 en_GB 2009 ProMinent GmbH Im Schuhmachergewann 5 11 D 69123 Heidelberg Germany Telephone 49 6221 842 0 Fax 49 6221 842 419 Email info prominent com Internet www prominent com...