10
Technical data
NOTICE!
Data sheet
This technical data supplements the enclosed data
sheet. If in doubt, the information on the data sheet
applies.
Type
Number of lamps
Lamp power
Connected power
1x80 W
1
90 W
110 W
1x230 W
1
260 W
310 W
1x350 W
1
370 W
430 W
Type
Minimum clearance for
maintenance work
Empty weight /
Operating weight
Reactor
Volume in litres
Gross/Net
1x80 W
720 mm
14.5 kg / 24 kg
11.0/10.4
1x230 W
1065 mm
19 kg / 32 kg
14.8/13.5
1x350 W
1465 mm
30 kg / 60 kg
30.8/29.0
Permissible operating temperatures:
n
Water temperature: 2 ... 40 °C
n
Ambient temperature: 0 ... 35 °C
Requirements for the water to be treated:
n
Maximum temperature: 40 °C
n
Maximum operating pressure: 10 bar
n
No corrosive or abrasive properties, chloride content < 250
ppm
n
No tendency for sedimentation
10.1 Control cabinet
Wiring diagram provided
A system-specific wiring diagram (appendix) is
delivered to you along with the UV system. In the
event of any differences between the operating
instructions and system-specific wiring diagram,
the system-specific wiring diagram applies.
UV control
Mains voltage V/Hz
230 (-10 %/+7 %) / 50/60
Fuse
Electronics and outputs, glass tube fuse, 4 A T
Maximum output load to be con‐
trolled
900 watts
Performance data
Technical data
37