Proluxe DP2000CE Operation Manual Download Page 1

 

Operations Manual 

Endurance X2 - Dual Heat Manual Dough Press - Model #: DP2000CE 

 

 

WWW.PROLUXE.COM 

Version: 41219 

Summary of Contents for DP2000CE

Page 1: ...Operations Manual Endurance X2 Dual Heat Manual Dough Press Model DP2000CE WWW PROLUXE COM Version 41219...

Page 2: ...rate 15 amp AC circuit Only industrial extension cords with proper wire size should be used size 16 3 wire for distance up to 25 feet and size 14 3 for distance up to 50 feet INTERNATIONAL Use a desig...

Page 3: ...antability and fitness for a particular use and is accepted such by the purchaser in taking delivery of this product Specifications Electrical 240V 50 60Hz 3000W 12 5Amps Requires 30 AMP outlet Includ...

Page 4: ...ke to change this setting simply follow the Controller Operation directions 2 Counter Cycle counter counts the number of applications from 1 to 9999 see additional Notes Counter 3 Timer A timer mode i...

Page 5: ...fferent products require different temperature settings In order to determine the right temperature setting for your product refer to the following table simply as a guide for starting To achieve cons...

Page 6: ...reen or in a pan Since the shape of the dough may be altered slightly in the transfer process some hand fitting may be required Add toppings if desired and now you are ready to bake ADDITIONAL NOTES T...

Page 7: ...should be followed Daily Care 1 Platens These platens should only be cleaned with mild soap and warm water then wiped off with a clean soft cloth or soft sponge Never use steel wool or harsh abrasives...

Page 8: ...on the right side of the vertical post Machines with swing away upper heads have two grease ports one on the right side of the vertical post and one on the back of the vertical post All other machines...

Page 9: ...gh LED segment check 8888 then to version and then loops back to to the above reboot The relay driver on the digital control may be blown Replace Digital Controller Digital display shows PROB No heat...

Page 10: ...alse reading as well Replace Relay If the Controller s heat on LED is not lit indicating the controller is working properly If this is not the issue replace sensor Dough not having same thickness acro...

Page 11: ...42 56 55 56 28 18 62 A2 A1 A3 20 A4 108 38 100 95 104 83 96 94 2X 102 95 103 95 94 98 2X 97 106 97 101 102 103 96 83 97 94 95 108 109 97 101 81 90 61 103 92 107 4X 109 105 103 105 22 06 01 18 EXPLOSI...

Page 12: ...4X 63 4X 53 4X 84 79 51 3X 66 65 29 5 25 70 17 67 41 31 44 30 69 35 38 8 34 17 70 5 17 33 A5 17 112 72 2X 35 43 33 42 27 81 56 79 55 56 38 55 36 74 75 38 73 43 10 78 19 47 35 12 4X 54 26 11 4X 64 39...

Page 13: ...POWER 220 AC European MPPW202 MPPW202 1 25 ORING 2 238 N 70 PISTON 238N70 238N70 1 26 WASHER STEEL 311 O D X 150 I D X 20 THK 311150019 311150019 4 27 MARKER STRIP TERMINAL BLOCK ARM 2 SINGLE MS6992 M...

Page 14: ...42034CP SST142034CP 1 73 FUSE HOLDER 1 AMP MPPF708 MPPF708 1 74 FUSE 1 AMP 250V 250W LOW BLOW MPPF701R MPPF701R 1 75 SCREW PHILLIPS PAN 2 56 x 1 4 SP25614 SP25614 1 76 FEET RUBBER RF209 RF209 5 77 ACT...

Page 15: ...33 50 FT 107 TERMINAL 6 RING x 18 22 GA 2202 2202 2 108 DP INSULATION 1101171251 1101171251 2 109 HEAT SHROUD 1109336 1109336 2 110 ASSEMBLY CAM RAMP 1109310 1109310 1 112 GEAR PINION 1109360 1109360...

Page 16: ......

Page 17: ...f the company s products the following instructions must be adhered to First contact our customer service department for approval and a return authorization number Please have the serial number of you...

Reviews: