background image

HARDWARE 

GUIDE

I/O Guide

Specifications and Operational Guide

REV. 6.1.7

PL-HRDW-I/O-EN

www.proloncontrols.com  |   [email protected]

17 510, rue Charles, Suite 100, Mirabel, QC, J7J 1X9

Summary of Contents for PL-C1000-BLR

Page 1: ...HARDWARE GUIDE I O Guide Specifications and Operational Guide REV 6 1 7 PL HRDW I O EN www proloncontrols com info proloncontrols com 17 510 rue Charles Suite 100 Mirabel QC J7J 1X9 ...

Page 2: ...troller 7 PL C1000 RTU RTUS Zoning Rooftop Controller Single Zone Controller 8 PL M2000 HP HPS Zoning Heatpump Controller Single Zone Heatpump Controller 9 PL C1000 HP HPS Zoning Heatpump Controller Single Zone Heatpump Controller 10 PL M2000 BLR Boiler 11 PL C1000 BLR Boiler 12 PL M2000 MUA Air Make Up 13 PL C1000 HU Humidifier 14 PL C1000 WLC Water Loop Controller 15 PL M2000 FLX FlexIO Controll...

Page 3: ...r Temperature Optional T1000 only T1000 T500 T200 General Purpose Analog Input 0 5 VDC 4 20mA 10K thermistor Supply Radiant Zone Occupancy Discharge Digital Sensor T1000 T500 or T200 Remote computer with Focus Analog Output 0 10 VDC Max Current 40 mA Network communication Digital Output Isolated Triac Dry Contact 24 VAC Max current 750 mA Power source of the controller 24 VAC Class 2 VC2000 ...

Page 4: ...ture sensor 10K thermistor Output 5 Analog 0 10VDC Max Current 40 mA Output 4 Isolated or Source TRIAC 24 VAC Max Current 300 mA Output 3 Isolated or Source TRIAC 24 VAC Max Current 300 mA Output 2 Isolated or Source TRIAC 24 VAC Max Current 300 mA Output 1 Isolated or Source TRIAC 24 VAC Max Current 300 mA Power source of the controller 24 VAC Class 2 T1000 T500 T200 Radiant Floor Temperature Opt...

Page 5: ...ional DO AO override based on outside temp Optional RJ45 Network communication Power source of the controller 24 VAC Digital Output Sink TRIAC 24 VAC Max current 300mA Analog Output 0 10VDC Max current 40mA Auxiliary Radiant Floor temperature sensor 10K thermistor NET A NET B 24 VAC COM DO DO AO COM AUX IN COM 1 2 3 4 5 6 7 8 9 10 ...

Page 6: ... Sensor RJ45 Interface communication Power source of the controller 24 VAC Auxiliary Radiant Floor temperature sensor 10K thermistor INT A INT B 24 VAC COM AUX IN COM 1 2 3 4 5 6 7 8 9 10 RJ45 Interface communication Power source of the controller 24 VAC INT A INT B 24 VAC COM 1 2 3 4 ...

Page 7: ...ptional Outside Temp Optional M2000 RTU C1000 RTU Outside Temp NC2000 Occupancy Optional Outside Temp Optional INFO RECEIVED FROM NETWORK PL M2000 RTUS 24 VAC AO 3 Bypass VSD AO 2 Economizer AO 1 Preheating Mod Heat DO 5 Heat W2 Exhaust Fan Baseboard DO 4 Heat W1 Preheat Perm DO 3 Cooling Y2 DO 2 Cooling Y1 DO 1 Fan G Bottom Row Common for all outputs Bottom Row Common for all inputs Static pressu...

Page 8: ...ht setback or proof of fan Supply air temperature sensor 10K thermistor Common for all inputs Return air temperature sensor 10K thermistor Outside air temperature sensor 10K thermistor Output 5 Analog 0 10VDC Preheating Heat W2 Output 4 Heat W1 Output 3 Cooling Y2 Output 2 Cooling Y1 Output 1 Fan G Controller s power source Unit s R C terminals 24VAC VC2000 C1000 VAV T1100 Zone Demand Unoccupied O...

Page 9: ...y Optional Outside Temp Optional M2000 HP C1000 HP Outside Temp NC2000 Occupancy Optional Outside Temp Optional INFO RECEIVED FROM NETWORK PL M2000 HPS 24 VAC AO3 Bypass VSD AO2 Economizer AO1 Preheating Mod Heat DO5 Aux Heat DO4 Rev Valve DO3 Compressor 2 Y2 DO2 Compressor 1 Y1 DO1 Fan G Bottom Row Common for all outputs Bottom Row Common for all inputs Static pressure 0 5 1 5V 1 1 5 2 2 5 in Ext...

Page 10: ...n Digital Temperature Sensor OR Incoming RS485 Network Communication Modbus HP INT Port Incoming RS485 Network communication Modbus HPS Net Port ProLon Digital Temperature Sensor OR Incoming RS485 Network Communication Modbus HP Net Port Outgoing RS485 Network communication to Zones Modbus VC2000 C1000 VAV T1100 Zone Demand Unoccupied Override C1000 HU INFO RECEIVED FROM NETWORK PL C1000 RTU Reque...

Page 11: ... 2 AO1 Dry Contact Return Water temp sensor 10K thermistor Proof of Pump 1 DO5 Dry Contact Supply Water temp sensor 10K thermistor Outside air temperature sensor 10K thermistor Controller s power source 24 VAC Class 2 INT Port Incoming RS485 Network communication Modbus NET Port Incoming RS485 Network communication Modbus M2000 RTU M2000 HP M2000 HYD C1000 RTU C1000 HP Occupancy Math values INFO R...

Page 12: ...roof of pump Supply water temperature sensor 10K thermistor Common for all the inputs Return water temperature sensor 10K thermistor Outside air temperature sensor 10K thermistor Output 5 Valve Modulating Boiler Analog 0 10 2 10 0 5 DVC Output 4 Boiler 2 Action Digital ON OFF Output 3 Boiler 1 Action Digital ON OFF Output 2 Pump 2 Action Digital ON OFF Output 1 Pump 1 Action Digital ON OFF Power s...

Page 13: ...ncoming RS485 Network Communication Modbus AO 3 Variable Frequency Drive AO 2 Cooling AO 1 Modulating Heat DO 5 Alarm DO 4 Preheat Permission DO 3 Fan DO 2 Outside Air Damper DO 1 Occupancy Exhaust NET Port Incoming RS485 Network communication Modbus CO2 4 20mA Building Pressure 0 5VDC Zone Temperature 10K Thermistor Outside Temperature 10K Thermistor Supply Temperature 10K Thermistor Manual Reset...

Page 14: ...ncoming RS485 Network communication Modbus External dry contact for proof of fan Supply humidity sensor 0 5VDC Common for all the inputs Room Return humidity sensor 0 5VDC Outside temperature sensor 10K thermistor Output 5 Humidifier Analog 0 10 2 10 VDC Output 4 Humidifier Digital ON OFF Output 3 Dehumidifier Digital ON OFF Power source of the controller 24VAC M2000 RTU M2000 HP M2000 HYD C1000 R...

Page 15: ...erature sensor 10K thermistor Auxiliary temperature sensor 10K thermistor Output 5 Water Tower Stage 2 Analog 0 10 VDC Output 4 Water Tower Stage 1 Digital ON OFF Output 3 Pump Digital ON OFF Output 2 Valve Damper Cooling Digital ON OFF Output 1 Boiler Digital ON OFF Power source of the controller 24VAC STAT NETSND NETREC INTSND A NET B OCC SUPPLY GND SETPT ROOM COM 24VAC COM 24VAC COM 24VAC COM 2...

Page 16: ...4 VAC Bottom Row Common for all outputs Bottom Row Common for all inputs Controller s power source 24 VAC RS485 Network Communication INT Port Analog Output 3 Analog Output 2 Analog Output 1 Digital Output 5 Digital Output 4 Digital Output 3 Digital Output 2 Digital Output 1 RS484 Network Communication NET Port Analog Input 9 Analog Input 8 Analog Input 7 Analog Input 6 Analog Input 5 Analog Input...

Page 17: ...ective owners REV 6 1 7 PL HRDW I O EN PL C1000 FLX FlexIO Controller PL C1000 FLX INT Port Incoming RS485 Network communication Modbus NET Port Incoming RS485 Network communication Modbus Digital Input Analog Input 3 Common for all the inputs Analog Input 2 Analog Input 1 Analog Output 0 10 2 10 0 5 VDC Digital Output 4 ON OFF PWM Digital Output 3 ON OFF PWM Digital Output 2 ON OFF PWM Digital Ou...