background image

HARDWARE 

GUIDE

Chiller Controller C1000 Series

Specifications and Operational Guide

REV. 7.3.1

PL-HRDW-CHL-C1000-C/F-EN

www.proloncontrols.com  |   [email protected]

17 510, rue Charles, Suite 100, Mirabel, QC, J7J 1X9

Summary of Contents for C1000 Series

Page 1: ...E GUIDE Chiller Controller C1000 Series Specifications and Operational Guide REV 7 3 1 PL HRDW CHL C1000 C F EN www proloncontrols com info proloncontrols com 17 510 rue Charles Suite 100 Mirabel QC J...

Page 2: ...Ds 7 Address Configuration for Networking 7 Input and Output Identification 8 Inputs 9 Temperature Sensors 9 Proof of Pump 9 Outputs 10 Output Specifications 10 Configuration of Digital Outputs 10 Typ...

Page 3: ...igure 7 Connnecting the Proof of Pump Contacts to the Controller 9 Figure 8 Output in SOURCE mode 10 Figure 9 Output in SINK mode 11 Figure 10 Connection of Active Outputs 3 and 4 11 Figure 11 Connect...

Page 4: ...ts and uses pre established control sequences that drive dedicated outputs to control standard Chiller equipment The main goal of this controller is to regulate the chilled water supply temperature Nu...

Page 5: ...ump status Water Supply Setpoint The target water supply temperature can be a simple fixed setpoint or instead follow a reset scale based on outside temperature return water temperature or even on a n...

Page 6: ...OURCE SINK dipswitch for Output 3 F SOURCE SINK dipswitch for Output 2 G SOURCE SINK dipswitch for Output 1 H Reset Button I Jumper to supply voltage to INT port see J J INT port for RS485 communicati...

Page 7: ...ious LEDs which are linked to different functions and outputs of the controller Each LED is individually identified to help the user make a quick visual diagnostic of the controller s activity and sta...

Page 8: ...r The RJ45 connector allows the use of premade CAT5 cables for simple plug and play RS485 communication This RJ45 connector follows the Modbus pinout specification for RS485 communication GND B A Figu...

Page 9: ...the network it can retrieve the outside temperature reading from one controller and distribute it to any other controllers on the network Figure 6 Connecting the Temperature Sensors Figure 7 Connnecti...

Page 10: ...on is performed via the Prolon Focus software An integrated resettable fuse protects each of the outputs of the C1000 against current surges and short circuits This protection will cut the current to...

Page 11: ...ntact to allow an external source to power the load Typical Connection of Digital Outputs 2 Switch position to obtain a SINK passive output Figure 9 Output in SINK mode Figure 10 Connection of Active...

Page 12: ...C1000 only provides the control signal to the load which is powered by an external source Figure 12 Connecting the Analog Output Controller Powered Figure 13 Connecting the Analog Output External Pow...

Page 13: ...All output power sources also originate from the controller s power source Figure 14 Connecting the 24VAC Power Source Figure 15 Connecting to the Network OUT1 COM 24VAC Supply N L 120VAC 24VAC The Pr...

Page 14: ...croprocessor Microprocessor PIC18F6722 8 bits 40 MHz 128KB FLASH memory Casing Molded ABS UL94 HB Communication Modbus RTU RS485 up to 127 nodes Baud rate 9600 19200 38400 57600 76800 115200 Connectio...

Page 15: ...ipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is n...

Page 16: ...erved No part of this document may be photocopied or reproduced by any means or translated to another language without prior written consent of Prolon All specifications are nominal and may change as...