Prolitec AirQ AQ1200 Original Instructions Manual Download Page 5

AQ/PS/RZ  1200

5

Chapter 2    

Cartridge Life & Room Size Table

Cartridge Life & Room Size Table

Estimating Cartridge Life

Estimating how long a cartridge will last and the number of days between services is critical to performing 
an installation that can be serviced efficiently. This includes determining the number of AQ1200s needed 
for a space. Please refer to AirQ’s ‘S3 (Sizing, Service & Success) Tool,’ available at 

AirQ Tools

. The chart 

below can be used as a rough guideline for sizing.

Room-Size Table

Normal Off-Cycle  

(NOC)

Short Off-Cycle 

(SOC)

Output Level 

Range

Room Volume Range

Room Volume Range

CFT

CM

CFT

CM

1-5

1800-8100

51-229

6000-25000

170-708

6-10

10000-17400

283-492

30000-47100

849-1333

11-15

19300-27700

546-784

51100-66300

1446-1876

16-20 

30000-39700

849-1124

70000-83600

1981-2366

21-25

42300-53400

1197-1511

86800-98900

2456-2799

26-30

56300-68600

1593-1941

101600-112000

2875-3170

31-35

71800-812000

2032-2425

114400-123500

3238-3495

36-40

89400-104800

2530-2966

125600-133600

3554-3781

41-45

108900-126200

3082-3571

135400-142300

3832-4027

46-50

130700-150000

3699-4245

143900-150000

4072-4245

These settings are suggested as a starting point. Start on the lower end of the range and adjust after one 
hour. Fragrance type, room size, number of fresh air changes per hour, temperature, humidity and user 
preference will determine the final setting. Best practice is to use AirQ’s ‘S3 Tool’ at 

AirQ Tools

.

Summary of Contents for AirQ AQ1200

Page 1: ...by Prolitec AQ PS RZ 1200 1200 SOC Original Instructions Rev 2015 05 15...

Page 2: ...r 7 OPERATING INSTRUCTIONS Unit Programming Setting Scent Intensity Scent Control Chapter 8 INSTALLATION Diffusion via HVAC system Installation Kit for Appliance Installation Kit for HVAC System DIffu...

Page 3: ...s retirement and assisted living facilities schools and restrooms A single AQ1200 can do both odor control and ambient scenting at the same time The AQ1200 with Prolitec odor control formulations and...

Page 4: ...ctly will meet the most demanding requirements Table 1 Prolitec AirQ Technology vs Aerosol Spray Can Technology Parameter Prolitec AirQ Technology Aerosol Spray Can Droplet Diameter m 1 50 Volume per...

Page 5: ...1 5 1800 8100 51 229 6000 25000 170 708 6 10 10000 17400 283 492 30000 47100 849 1333 11 15 19300 27700 546 784 51100 66300 1446 1876 16 20 30000 39700 849 1124 70000 83600 1981 2366 21 25 42300 5340...

Page 6: ...upper respiratory discomfort This appliance is not intended for use by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supe...

Page 7: ...ted nature of the fragrances may make the scent difficult to remove from hands and skin Wash your hands after all contact with Cartridges or fragrance While AirQ Air Treatment Agents do not contain in...

Page 8: ...Controls Appliance Controls Hose Clamp Hose Connector Air Nozzle Recyclable Cartridge First Stage Air Filter Control Display Program Selector Control Buttons Battery Tab Injector Hose DC Power Jack s...

Page 9: ...m the cartridge output port and pulling out 5 Remove cartridge from appliance enclosure 6 Install new cartridge place and tighten hose connector firmly on cartridge output port 7 Insert air nozzle and...

Page 10: ...lter should be replaced To replace it unscrew the 3 knobs to open the panel and exchange the filter after pulling off the rubber tubing from both sides of the filter Note the small triangle showing th...

Page 11: ...mmet The battery is located on the lower front corner of the silver bracket 3 Insert the new CR2032 battery The positive side of the battery should face your right while looking at the front of the ap...

Page 12: ...ns to select the day You can set maximum of 3 on off programs same for every day or individually for each day After selecting the day press the Set button to advance Now the 1 icon is turned on to ind...

Page 13: ...ogram and set the intensity level with the keys You will see the level numbers 1 to 50 on the right side of the screen Hint There are many variables to finding the scent level that works size airflow...

Page 14: ...200 appliance not pictured with 2 Four 4 drywall anchors for mounting in drywall 3 Four 4 lead anchors for mounting in concrete 4 Four 4 screws and 4 washers for mounting in drywall and concrete 5 Fou...

Page 15: ...to be targeted for air treatment 2 Determine the Air Handling Unit or duct that serves the target area 3 Make sure the AHU does not use an open gas flame 4 Find and mark the optimal insertion point fo...

Page 16: ...er steam chilled water and DX coils Open gas flames should absolutely be avoided If installation must be over gas heated coils or open gas flames contact Prolitec Technical Support The best location f...

Page 17: ...AC plug to the cord and connect to a nearby outlet Open the enclosure door and unscrew the aluminum cap of the waterproof collar located on top of the appliance enclosure Remove and set aside the gro...

Page 18: ...section of duct and far away from any turns branches or cross section changes as practical and not immediately after the supply fan 1 At the insertion point drill a hole using a drill bit 2 Insert th...

Page 19: ...uded 1 One 1 AQ1200 appliance not pictured with 2 Four 4 dry wall anchors for mounting in drywall 3 Four 4 lead anchors for mounting in concrete 4 Four 4 screws and 4 washers for mounting in drywall a...

Page 20: ...One 1 Prolitec Diffusion fan and cable for direct indoor diffusion 2 Three 3 drywall anchors for mounting fan onto dry wall 3 Three 3 lead anchors for mounting in concrete 4 Three 3 screws for mountin...

Page 21: ...Place the appliance onto the desired location on the wall and ensure that it is level 2 Fasten the appliance to the wall using the necessary anchors screws and washers provided 3 Open the enclosure d...

Page 22: ...ng holes Fig 4 3 For installation on drywall drill the 3 anchors into drywall and install the 3 screws to secure the diffusion fan to the wall Use the metal screws provided for installation on sheet m...

Page 23: ...11 If needed use a flat head screw driver to push in the side wall of the cable raceway Fig 12 Fig 13 Fig 14 7 Insert cable connector into jack located on the right side of the appliance Fig 12 8 Ext...

Page 24: ...ace Increase the output rate by one or two settings and evaluate detection in 30 minutes Repeat as needed If consumption requires cartridge change more frequently than each month install an additional...

Page 25: ...t tube Check and remove it The air intake may be blocked Another method for clearing obstructions is while the appliance compressor is running block the output tube with a finger for a few seconds and...

Page 26: ...ot paint or otherwise try to alter the color of the outer cover Always keep the cap and plug on cartridges when stored outside of the AQ1200 Do not operate AQ1200 in very dusty areas that may cause th...

Page 27: ...C at 0 6A Frequency 50 60 Hz Protection Switching power supply Internal Power 12V DC at 1 5 A Battery Lithium 3V CR2032 Approvals UL CSA listed Power Supply Working Temperature 0 to 40 C Working Humid...