Cartridge Change
When the reservoir is empty the cartridge needs to be changed. The change process is simple. Best
practice is to wear gloves when manipulating the cartridge.
1. Unlock and open the door of the cartridge housing.
2. Turn off the power by pressing the power button.
3. Grab the cartridge and disconnect air stem and plume kit.
4. Inspect the air stem seal for damage. Replace if damaged.
5. Remove plugs from new cartridge and use them to plug empty cartridge.
6. Deliver empty cartridge to recycling center at a later date.
7. Connect new cartridge to air stem and plume kit, and seat in appliance.
Cartridge Change Maintenance Checklist Items
Cartridge plume: Use a high-intensity flashlight or your headlamp to confirm that a plume is
streaming from the output port. If there is no plume:
• Check that the power is on and the appliance is running.
• Check that the wipers on the air stem are in place and not cracked or broken. Replace if
necessary.
• If the appliance is set to
Run Program
, switch it to
24/7
and check for a plume.
• If no plume, set it back to
Run Program
and change the cartridge.
• If still no plume, try another cartridge just to make sure. If no plume, replace the appliance.
• Wipe the unit clean inside and out.