2. IN GENERAL

The pumps in the catagorie Centrifugal Pumps are developed according to the newest stand of 

technology, manufactured with much care and go under strict intensive controls.

The pumps have been optimized by us especially for the special requirements for circulating 

and filtering large volumes of water. Make sure after unpacking the pump that the data given 

on the type label agree with the included operating instructions. In the case of doubt the  pump 

is not to be used. Transport damages are immediately to be reported to the package distributor 

and to us in witten form.

3. RANGES Of APPLIcATION

These pumps are made for pumping clear water (free of mud and sand, see technical data)

The pumps are made for the following ranges of application:

l

 In private and in public swimming pool

l

 Circulating large volumes of water

l

 Other Clear water pumping

2 English

SAfETy INSTRUcTION AND WARNINGS

Please read the user manual 

before using the device

Pull power plug

Warning sign

Warning of electrical voltage 

1. INTRODUcTION

We would like to congratulate you on the purchase of our pump. We appreciate your trust. 

That‘s why funtional security and operational safety stands by us on first place.

  

To prevent damage to persons or property, you should read this user manual 

carefully. Please observe all safety precautions and instructions for proper use 

of the pump. failure to follow the instructions and safety precautions can result 

in injury or property damage.

  Please keep this manual with the instructions and safety instructions carefully 

in order to at any time you can restore them. Please always download the latest 

version of the user manual of www.profi-pumpe.de under „downloads“. This 

shall always prevail.

IMPORTANT!

The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any 

guarantee is void in case of improper use. They are not suitable for pumping flammable liquids 

or for use in places where there is danger of an explosion. The pumps are designed for home 

use in the house and garden. 

These pumps are intended for private use in the home and garden. These pumps are not desi-

gned for continuous use (without interruptions). In continuous operation mode, the lifetime will 

be shortened accordingly. Never run more than 5 minutes against a closed valve pump. Save 

the pump against dry running (install dry run protection). 

Never start and stop the pump more than 20 times per hour. When the pump clocks, any 

claim under warranty is void.

Not suitable for use with solar photovoltaic panels.

English 3

4. OPERATION

 

The installation must be performed by a qualified professional.

 

 Please, check each time before using, the electrical connections and the cables are not 

damaged. Check before the installation whether the electrical connections are earthed 

according to the statutory regulations and are installed. The pump is to be secured 

through a RCD circuit breaker with release current of 30 mA. is technically correct, so 

this warranty is void. It must be ensured that the pump is sufficiently cooled during pro-

longed operation.

It is not recommended to perform even cable extensions or any other technical modifications. The 

lines to the pump must be installed always steadily rising. A transfer of mechanical loads or vibra-

tions from the pump or to the pump must be eliminated through appropriate actions (use of rubber 

buffers, braided hoses, line fixation, etc.).

Do not reduce the suction line. All pipe/hose connections to and from the pump must be sealed. We 

recommend that you implement the suction line „as one piece“ without any interruption in order to 

prevent and avoid leaks. Check pump and water lines for leaks by pressure testing min. 24 hrs.

Is dirt expected  in the pump, an effective pre-filter should be installed before the pump inlet. Fill 

pump and suction

pipe/hose with water. Please connect electrically pump with power supply. Start the pump. If neces-

sary, the pump and the suction line must be refilled until a normal continuous operation has been 

established.

NOTE: 

Please note that a tapering of the pump connections may cause a defect in the pump. Here, 

the terminal sizes specified should be strictly adhered to. With strong restriction of flowthrough on 

the pressure side of the pump (for example, due to clogged sand filter) water can come out of the 

housing.

Fan cover

Permanent

magnet 

motor

Cover

Base Input Pump head Pressure tank

LED display

Filling pipe Outlet

5. BEDIENUNG

l

  Please open the cap of the filler neck, fill in as 

much water as is needed to allow it to escape 

from the neck, turn the cap back in clockwise 

after filling the water.

l

  Connect the power supply, the display shows 

„0.0“ bar. 

l

  Set the pressure display range to display the set 

pressure value, the power indicator lights up.

l

  Open the discharge valve, press the „

RUN

“ but-

ton, start the pump.

l

  Under all operating conditions, pressing the 

„STOP“ button stops the pump.

contents

  1.  Introduction  ..........................................................................................................................  2

  2.  In general  .............................................................................................................................  2

  3.  Ranges of application  ..........................................................................................................  2

  4.  Installation  ...........................................................................................................................  3

  5.  Operation  .............................................................................................................................  3

  6.  Buttons and functional discription  ........................................................................................  4

  7.  Security tips  .........................................................................................................................  5

  8.  Servicing  ..............................................................................................................................  5

  9.  Guarantee regulations  .........................................................................................................  6

10 . Recognising and repairing of mistakes  ................................................................................  6

11.  Notes on Product Liability  ....................................................................................................  6

12.  Notes on Disposal  ...............................................................................................................  7

13.  EU Declaration of Conformity  ..............................................................................................  7

14.  Technical Data  ...................................................................................................................  16

Summary of Contents for INVERT-TECH2

Page 1: ...nformation about our products can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG INVERTER DOMESTIC WATERWORKS INVERTER HAUSWASSERWERK Version 19 08 de ...

Page 2: ...taic panels English 3 4 Operation The installation must be performed by a qualified professional Please check each time before using the electrical connections and the cables are not damaged Check before the installation whether the electrical connections are earthed according to the statutory regulations and are installed The pump is to be secured through a RCD circuit breaker with release curren...

Page 3: ...s repeat the procedure Key function and display description NO NAME Description 1 Stop button The pump can be stopped manually press this button to exit the of water state 2 Operation button The pump can be stopped manually press this button to exit the of water state 3 working state Indicates that the motor is in working state 4 Actual pressure Display the actual pressure value of the current pip...

Page 4: ...our service platform http www profi pumpe de service php We will inform you how to proceed with case related Returns please sufficient postage Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery Our service we provide in Germany The warranty does not cover l Material wear sealing rings impeller wheels impeller chambers l Unjustified interventions or ...

Page 5: ...m jederzeit darauf zurückgreifen zu können Bitte laden Sie stets die neueste Ausführung der Bedienungsanleitung von www profi pumpe de unter download herunter Diese ist stets maßgebend 4 Inbetriebnahme Die Installation ist von einer qualifizierten Fachkraft auszuführen Bitte überprüfen Sie vor jeder Inbetriebnahme die elektrischen Anschlüsse sowie das Kabel auf Unversehrtheit Bitte prüfen Sie vor ...

Page 6: ...st die Installation abgeschlossen Falls Sie Unregelmäßigkeiten feststellen muß der Vorgang wiederholt werden 6 Tasten und Funktionsbeschreibung Tastenfunktion und Display Beschreibung Nr NAME Beschreibung 1 Stopptaste Um die Pumpe manuell zu stoppen drücken Sie die Stopptaste 2 Betriebstaste Auch mit dem Drücken der Betriebstaste kann die Pumpe gestoppt werden 3 Betriebsstatus Zeigt an dass die Pu...

Page 7: ...esetzliche Gewährleistung In diesen Fällen überneh men wir den Umtausch oder die Reparatur der Pumpe Versandkosten werden von uns nur getragen soweit dies gesetzlich vorgeschrieben ist Im Garantiefall bitte über unsere Serviceplattform http www profi pumpe de service php den Fall an melden Dann teilen wir Ihnen die weitere Vorgehensweise fallbezogen mit Rücksendungen bitte ausreichend frankieren U...

Page 8: ...12 Notes Notizen 13 Notes Notizen ...

Page 9: ...a English Deutsch HW01115 Power P1 Leistung P1 1000 W Max pump capacity Max Fördermenge 4 3 m h Max pressure Max Druck 5 bar Max pump height Max Förderhöhe 50 m Max water temperature Max Wassertemperatur 60 C Protective class Schutzklasse IPX5 Tension Spannung 230V 50 Hz Measures in mm Maße in mm 404x183x240 Connection in out Anschlüsse 1 Cable length Kabellänge 1 5 m Schematic illustration as an ...

Reviews: