15-32
Redundancy (Switch 8212zl)
Existing CLI Commands Affected by Redundant Management
Figure 15-24. Example of boot set-default Command Defaulting to Secondary Flash
Reload Command
The
reload
command boots the active management module from the current
default flash (You can change the default flash with the
boot set-default
command. See “Setting the Default Flash for Boot” on page 15-31). Switchover
occurs if redundancy is enabled and the standby management module is in
standby mode. If redundancy is disabled or the standby management module
is not present, the
reload
command boots the system.
N o t e
The reload command is a “warm” reboot; it skips the Power on Self Test
routine.
ProCurve(config)# show flash
Image Size(Bytes) Date Version Build #
----- ---------- -------- ------- -------
Primary Image : 7463821 03/05/07 K.12.XX 351
Secondary Image : 7463821 03/05/07 K.12.XX 351
Boot Rom Version: K.12.01
Default Boot : Primary
ProCurve(config)# boot set-default flash secondary
This command changes the location of the default boot. This
command will change the default flash image to boot from
secondary. Hereafter, ‘reload’ and ‘boot’ commands will boot
from secondary. Do you want to continue [y/n]? y
ProCurve(config)# show flash
Image Size(Bytes) Date Version Build #
----- ---------- -------- ------- -------
Primary Image : 7463821 03/05/07 K.12.XX 351
Secondary Image : 7463821 03/05/07 K.12.XX 351
Boot Rom Version: K.12.01
Default Boot : Secondary
3500-5400-6200-8200-MCG-Jan08-K_13_01.book Page 32 Monday, January 28, 2008 10:04 AM