Procon Grumbach CTD7 Operating Manual Download Page 1

 

 
 

 
 
 

 
 

 
 

 
 
 

 
 

 
 
 

 
 

 
 

 
 

Manual for Incubator 

 

Operating Manual for Incubator 

 
 

CTD7 

 

 

Summary of Contents for Grumbach CTD7

Page 1: ...Manual forIncubator Operating Manual for Incubator CTD7...

Page 2: ...Cleansing and disinfection 8 Operation 10 Technical data 11 Service 11 Home 12 Menu 13 1 Temperature and humidity target 14 2 Cooling Phases 15 3 Rotation phase 16 4 Offset temperature unit 17 5 Brood...

Page 3: ...3 12 Info page 26 Web browser 27 1 Home 27 2 Calendar 28 3 Graph 29 2 Logs 30 3 Website ProCon Grumbach 31 Breeding recommendation 32 attachment 1 Privacy Policy 33...

Page 4: ...refrom are the sole responsibility of the user A liability or guarantee for the correctness of the provided results data is excluded Under no circumstances will liability be assumed for damages result...

Page 5: ...ty socket which is according to the regulations your incubator is operational Safety thermostat Additionally we installed a safety thermostat in all incubators which prevents over heating For safety r...

Page 6: ...d the pointed ends point towards each other This prevents a rolling away of the eggs into one direction Always fill the trays from the middle to the outside to support the air circulation The eggs sho...

Page 7: ...to do the hatching in the same incubator suit the temperature and the humidity to the eggs Take out the trays with rollers and put the eggs on the grating floor It is often more favorable to put the...

Page 8: ...and the incubator has been cleaned thoroughly it should be left open so the humidity left in the incubator can escape Before the next incubating it is necessary to clean the filter and change the filt...

Page 9: ...ments thermometer operating elements controls test run water sterilized by boiling trouble free running Applies to all menu items All values which have to be changed during operation in the menu are d...

Page 10: ...10 Operation 1 Premium Touch Display 2 Main switch 3 Waterfill in Waterdrainplug 4 Tank flap 5 Fresh air 6 Egg trays with rollers 7 Security thermostat...

Page 11: ...5 Fax 49 49 0 64 00 956 91 29 E mail info grumbach brutgeraete de Internet www grumbach brutgeraete de Important Since 1 January 1996 the CE marking has been compulsory in conjunction with the EMC Dir...

Page 12: ...ease check the filters regularly every eight days In the case of young animals with plumage dust 1 menu home 2 page back 3 page forward 4 temperature 5 humidity water tank 6 cooling 7 turn unlock 8 Se...

Page 13: ...erature and humidity set points 2 Cooling phases 3 Rotation phases 4 Offset and temperature unit 5 Breed calendar screen lock logging 6 Threshold values 7 Email and internet connection 8 Display and l...

Page 14: ...ome screen by touching the temperature or humidity Note If the slider and the buttons are disabled grayed out the calendar is active see Under point 5 Brood Calendar data logging went language 1 Set p...

Page 15: ...of the room Note If the slider and the buttons are disabled grayed out the calendar is active see Under point 5 Brood Calendar data logging went language 1 Cooling phase length 1 90 minutes 2 When act...

Page 16: ...rayed out the calendar is active see Under point 5 Brood Calendar data logging went language 1 Rotation time 1 30 minutes 2 When activated the set rotation time will vary by up to 30 3 Rotations per d...

Page 17: ...in the highest possible accuracy of temperature and relative humidity we recommend you the use of the supplied Capillary Thermometer and Hair Hygrometer 1 corrected temperature 2 corrected humidity 3...

Page 18: ...in the Web browser are accepted see Web browser Sub 2nd Calendar 1 Selection of breeding start day 2 Automatic screen lock To unlock press the cooling icon bottom right for 3 seconds 3 Activation of t...

Page 19: ...lerance value the background color of the temperature humidity changes to red as well as a corresponding error on the error page is visible In addition the alarm is also triggered if there is no appro...

Page 20: ...ack emails about the state every n hours as well as live data of the incubator by browser Note Default is 0 hrs inactive 1 Email address Enter email address for alert and status emails 2 Alarm interva...

Page 21: ...Device description display settings By adjusting the display brightness you get the possibility to reduce your power consumption 1 Background color Background image 2 Display brightness 3 Language set...

Page 22: ...regulation is interrupted The stopwatch runs when the test switch and the rotary switch are pressed It stops as soon as the rotary switch is confirmed again When switching to another side the normal...

Page 23: ...pecified network in the network area 192 168 40 8 With the IP 192 168 40 1 Computers can then automatically connect to it This setting is not recommended for existing DHCP on the network Note The sett...

Page 24: ...twork address Server creates a hotspot with specified network IM Network Area 192 168 40 8 with IP 192 168 40 2 1 Activating the connection 2 Displays available networks 3 Data of the WLAN Network you...

Page 25: ...he background color of the bottom icons on the main screen is colored red an error occurred Those errors can be looked up here 1 Breeding time of the last connection to the regulation processor 2 List...

Page 26: ...26 12 Info page 1 Here you can enter a description of the device 2 List of the complete duration of your incubator microcontroller version display version device type serial number 3 Contact...

Page 27: ...uilt a working Netzwerkverindung you can connect to your favorite PC smartphone via a browser The address which must be entered in the browser can be found on the Ethernet or WiFi page in the display...

Page 28: ...lete With Save You can download your settings to your PC and read them back with the button browse if desired Transfer will eventually send the settings to your incubator For security reasons these mu...

Page 29: ...og be patiend till the diagramm is build up entirely on your Browser In the lower graph area you can zoom by marking the time area Single Linevaluesets can be blended out by clicking there names on th...

Page 30: ...easurement results conclusions and measures derived therefrom are exclusively subject to the user s own responsibility A liability or guarantee for the correctness of the provided results data is excl...

Page 31: ...page and click Submit On this page you will see new data of the machine in 60 seconds Note The incubator must have access to the Internet via The network Furthermore the Cloudupload must be activated...

Page 32: ...10 day 2timesdailyuntilpicking Turning 2 22 day 3 6timesdaily Candeling 14 17 22 day Parrot breeding Temperature Humidity Cockatoo 37 1 37 2 C 38 42 relativehumidity Macaw 37 1 37 2 C 48 relativehumid...

Page 33: ...rmore data subjects are informed by means of this data protection declaration of the rights to which they are entitled As the controller the ProCon automatic systems GmbH Co KG has implemented numerou...

Page 34: ...rofiling means any form of automated processing of personal data consisting of the use of personal data to evaluate certain personal aspects relating to a natural person in particular to analyse or pr...

Page 35: ...pliance with the applicable data protection rules according to the purposes of the processing j Third party Third party is a natural or legal person public authority agency or body other than the data...

Page 36: ...ta will be rectified or erased or further processing suspended Personal data shall not be kept in a form which permits identification of the Data Subjects for longer time than necessary for the purpos...

Page 37: ...a special personal data about you unless you have provided your explicit consent thereto or we are required to do in order to comply with applicable regulation 5 Our purposes for processing your perso...

Page 38: ...es of processing of data collected by the use of cookies are the following to operate improve and optimise the performance and user experience of the website and its services perform customer and user...

Page 39: ...ss of processing conducted prior to the withdrawal Further as a consequence of your withdrawal of your consent we may not be able to satisfy your requests or provide you with our services 9 Data Secur...

Page 40: ...ance of a contract with you In order to make use of any of the rights mentioned above please contact us via the points of contacts listed in section 16 With regard to such requests kindly provide us w...

Page 41: ...41 We reserve the right to amend this Privacy Policy in the future due to changes in applicable legislation We will inform you of any such amendments...

Reviews: