OPERATION

 WARNING: If you do not fol-

low these instructions exactly, 

a  fire  or   explosion  may  result 

causing property damage, per-

sonal injury or loss of life.

A.  This appliance has a pilot which must 

be lighted by hand. When lighting the 

pilot, follow these instructions exactly.

B.  BEFORE  LIGHTING  smell  all  around 

the appliance area for gas. Be sure to 

smell next to the floor because some 

gas is heavier than air and will settle 

on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn 

the gas control knob. Never use tools. 

If  the  knob  will  not  push  in  or  turn 

by  hand,  don’t  try  to  repair  it,  call  a 

qualified service technician. Force or 

attempted repair may result in a fire or 

explosion.

D.  Do not use this appliance if any part 

has been under water. Immediately call 

a qualified service technician to inspect 

the appliance and to replace any part of 

the control system and any gas control 

which has been under water.

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

 WARNING: You must oper-

ate this heater with the screen 

in  place.  Make  sure  screen  is 

installed before running heater.
NOTICE: During initial operation of 

new heater, burning logs will give 

off a paper-burning smell. Orange 

flame will also be present. Open 

damper or window to vent smell. 

This will only last a few hours.

1.  STOP! Read the safety information above.

2.  Open screen.
3.  Make sure equipment shutoff valve is fully 

open.

4.  Turn control knob clockwise 

 to the 

OFF position (see Figure 21).

5.  Wait five (5) minutes to clear out any gas. 

Then  smell  for  gas  around  heater  and 

near  the  floor.  If  you  smell  gas,  STOP! 

Follow "B" in the safety information above. 

If you do not smell gas, go to the next step.

6.  Turn control knob counterclockwise 

 

to  the  PILOT  position.  Press  in  control 

knob for five (5) seconds.

 

Note:  The  first  time  that  the  heater  is 

operated after connecting the gas supply, 

the control knob should be pressed for 

about thirty (30) seconds. This will allow 

air to bleed from the gas system. If pilot 

does not stay lit, refer to Troubleshooting, 

pages 24 though 27. Also contact a quali-

fied service technician or gas supplier for 

repairs. Until repairs are made, light pilot 

with match.

• If control knob does not pop up when 

released,  contact  a  qualified  service 

technician or gas supplier for repairs.

Ignitor

ON/OFF 

Switch

Control Knob

Figure 21 - Heater Control Locations

Summary of Contents for FBNSD400T-ZC Series

Page 1: ...mmediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be perform...

Page 2: ...of this manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures...

Page 3: ...low fans to blow directly into the heater Avoidanydraftsthatalterburner flame pattern including ceiling fans Altered burner patterns can cause sooting SAFETY WARNING Do not attempt to access or change...

Page 4: ...oducts may create a white powder residue within burner box or on adjacent walls or furniture 8 Always run heater with control knob at PILOT IGN or ON 1 thru 5 positions never set control knob between...

Page 5: ...h air PIEZO IGNITION SYSTEM This heater is equipped with an electronic piezo control system This system requires AAA batteries provided THERMOSTAT HEAT CONTROL The control automatically cycles the bur...

Page 6: ...alth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachuset...

Page 7: ...erfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods help reduce...

Page 8: ...nto adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From...

Page 9: ...or ash clean out doors located on floor or wall of fire place If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the h...

Page 10: ...ill be pushed back by the fitting making all of the adjustments for the gas being supplied DO NOT REMOVE THE PLUNGER The regulator will not work and the warranty will be voided Theinletregulatoriscolo...

Page 11: ...eshelf3 8 NPTpipe cap This will damage the plung ers located inside the regulator DO NOT TRY TO REMOVE THE PLUNGERS FROM INSIDE THE REGULATOR THE PLUNGER WILLBEPUSHEDBACKASTHE FITTINGISINSTALLED REMOV...

Page 12: ...should not be less than 12 see Figure5 B Clearance from the top of the fireplace to the ceiling must not be less than 48 BUILT IN FIREPLACE INSTALLATION WARNING Do not allow any combustiblematerialsto...

Page 13: ...standoff brackets in the hardware bag Remove screws from the top of the firebox Install brackets with screws as shown in Figure 10 3 Carefully set fireplace in front of rough opening with back of fir...

Page 14: ...p is an acceptable al ternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice technician must connect heater...

Page 15: ...f you do not reduce incom Figure 12 External Regulator with Vent Pointing Down External Regulator with Vent Pointing Down Propane Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Ni...

Page 16: ...Ifbubblesform there isaleak Correctallleaksatonce PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect heater with its appliance main gas valve control v...

Page 17: ...s very important to install the logs exactly as instructed Do not modify logs Use only logs supplied with heater Each log is marked with a number This number will help you to identify the logs when in...

Page 18: ...ct For long periods of non operation remove batteries from all components for safety Unscrew ignitor cap and install a AAA battery with the pointing out Replace cap Figure 20 Installing Battery in Ign...

Page 19: ...n under water FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS WARNING You must oper ate this heater with the screen in place Make sure screen is installed before running heater NOTICE Durin...

Page 20: ...starting again 10 Make sure heater screen is in place before operating heater 11 If heater will not operate follow the in structions To Turn Off Gas To Appliance and call your service technical or ga...

Page 21: ...ping follow instructions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame App...

Page 22: ...irt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner Rep...

Page 23: ...air through the air inlet hole You may blow through a drinking straw if compressed air is not available CABINET ODS PILOT Air Passageways Use a vacuum cleaner or pressurized air to clean Exterior Use...

Page 24: ...pressure switch See instructions below The entire gas delivery piping including con nections inside the heater should be leak tested by the qualified installer After leak testing the qualified instal...

Page 25: ...rn control knob to PILOT position 3 Fully press in control knob while pressing ignitor button 4 Continue holding down control knob Repeat igniting operation until air is removed 5 Clean ODS pilot see...

Page 26: ...oo low 3 Gas regulator is defective 1 Check burner for dirt and debris If found clean burner see Care and Maintenance page 22 2 Contact local gas supplier 3 Replace gas train Slight smoke or odor duri...

Page 27: ...noise is exces sive contact qualified ser vice technician White powder residue forming within burner box or on adjacent walls or furniture 1 When heated the vapors from furniture polish wax carpet cle...

Page 28: ...www usaprocom com 200348 01C 28 PARTS MODEL FBNSD400T ZC 7 8 1 5 2 3 6...

Page 29: ...page 30 of this manual ITEM PART DESCRIPTION QTY 1 161818 01HT Hood 1 2 161368 01HT Left Door Assembly 1 3 161369 01HT Right Door Assembly 1 5 161822 01 Gas Train Assembly 1 6 161338 01 Ignitor 1 7 1...

Page 30: ...c at 1 866 573 0674 for information EQUIPMENT SHUTOFF VALVE For all models Equipment shutoff valve with 1 2 NPT tap Model and serial number of your heater How heater was malfunctioning Type of gas use...

Page 31: ...ified heat propane gas supply might be low propane units only You may feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SERVICE You may have further questions about ins...

Page 32: ...rt s MUST be obtained through ProCom Heating Inc who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be...

Reviews: