INSPECTING BURNERS
IMPORTANT: Owner’s should check pilot flame pattern and burner flame pattern often.
Incorrect flame patterns indicate the need for cleaning (see Care and Maintenance,
page 24) or service.
WARNING: Only a qualified service person should service and
repair heater. This includes maintenance requiring replacement or
alteration of components.
PILOT FLAME PATTERN
Figure 28 shows a correct pilot flame pattern.
Figure 29 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching
the thermocouple. This will cause the ther-
mocouple to cool, which shuts the heater off.
If pilot flame pattern is incorrect, as shown
in Figure 29
• turn heater off (see
To Turn Off Gas to Ap-
pliance
, page 20)
• see
Troubleshooting
pages 26 through 31.
WARNING: If yellow tipping
occurs, your heater could pro-
duce increased levels of carbon
monoxide. If the burner flame
pattern shows yellow tipping,
follow instructions at bottom of
this page.
Notice: Do not mistake orange flames with
yellow tipping. Dirt or other fine particles enter
the heater and burn causing brief patches of
orange flame.
Approx. 3"-6" Above Top of Logs
More Than 8" Above Top of Logs
Approx. 3"-6" Above Top of Logs
More Than 8" Above Top of Logs
Figure 30 - Correct Burner Flame Pattern
Figure 31 - Incorrect Burner Flame
Pattern
BURNER FLAME PATTERN
Figure 30 shows a correct burner flame pattern. Figure 31 shows an incorrect burner flame
pattern. If burner flame pattern is incorrect then:
• turn heater off (see
To Turn Off Gas to Appliance
, page 20).
• see
Troubleshooting
pages 26 through 29.
BURNER PRIMARY AIR HOLES
Air is drawn into the burner through the holes in the fitting at the entrance to the burner. These
holes may become blocked with dust or lint. Periodically inspect these holes for any blockage
and clean as necessary. Blocked air holes will create soot.
Figure 28 - Correct Pilot Flame Pattern
(Natural Gas shown)
Figure 29 - Incorrect Pilot Flame Pattern
(Natural Gas shown)
NG
3-3.5" WC
Natural Gas
Shown
LP
8-11" WC
NG
3-3.5" WC
Natural Gas
Shown
LP
8-11" WC