COMPACT  VENT-FREE
FIREPLACE  SYSTEM

OWNER

S OPERATION AND INSTALLATION MANUAL

Do  not  store  or  use  gasoline  or  other  flam-
mable vapors  and  liquids  in  the  vicinity  of
this  or  any  other  appliance.
WHAT  TO  DO  IF  YOU  SMELL  GAS

 

Do  not  try  to  light  any  appliance.

 

Do   not   touch   any   electrical   switch;

do  not use  any  phone  in   your  building.

  Immediately   call   your  gas  supplier  from

a  ne ighbor ’s     phone.    Follow     the      ga s
supplier’s
 instructions.

 

If   you   cannot  reach  your  gas  supplier,

call  the  fire  department.
Installation  and  service  must  be  performed
by  a  qualified   installer, service   agency, or
gas  supplier.

        WAR N I N G :

 

  I mp r o p e r       i n s t a ll a t io n ,

adjustme nt, alteration, service  or  mainte-
nance can  cause  injury  or  property  damage.
Refer  to  this  manual  for  correct  installation
and operational  procedures.  For  assistance
or  additional  information  consult  a  quali-
fied  installer,  service  agency  or  gas  supplier.

This  appliance  may  be  installed  in  an
aftermarket*,  permanently  located, manufac-
tured (mobile) home, where  not  prohibited
by  local  codes.

This appliance  is  only  for  use  with  the  type
of  gas  indicated  on  the  rating  plate. This
appliance  is  not  convertible  for  use  with
other  gases.

*Aftermarket: Completion  of  sale, not  for  pur-
pose  of  resale,  from  the  manufacturer.

Safety Information Warnings.......................................2

Air for Combustion and Ventilation............................4

Installation......................................................................6

Operating heater...........................................................9

Cleaning&Maintenance.............................................10

Trouble Shooting.........................................................11

Specifications..............................................................13

Replacement Parts.....................................................14

Parts List.......................................................................16

Installing the Heater....................................................21

Installing Blower Accessory.......................................22

Installer: Please leave these instructions with the
consumer.

Consume r: Please retain these instruc-
tions for future use.

    

WARNING:

 

 If  the  information  in

this  manual  is  not  followed  exactly,
a     f ir e     o r   e x p lo sion     ma y   r e s ult
causing  property  damage,  personal
injury,  or  loss  of  life.

    WARNING:

   

This  is  an  unvented

gas-fired heater.  It  uses  air  (oxygen)
f r o m     t h e     r o o m    i n     w h i c h     it     i s
installed.  Provisions  for  adequate
combustion  and  ventilation  air  must
b e     p r o v i d e d .     R e f e r     t o    Air     F o r
Combustion  and  Ventilation section
on  page  4  of  this  manual.

WATER VAPOR:

A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion.
An unvented room heater produces approximately
one (1) ounce (30ml) of water for every 1,000 BTU’s
(3KW’s) of gas input per hour. Refer to page 3.

Tabel of Contents

EN250TYLA-B

EL250TYLA-B

EN250TYLA-W

EL250TYLA-W

EN250TYLB-O

EL250TYLB-O

EN250TYLB-C

EL250TYLB-C

EN250TYLB-DO

EL250TYLB-DO

PR-EL026-01-0803

CONTINENTAL APPLIANCE INC/U.S. OFFICE

5 Musick   

      

 4600 Highlands  Parkway S.E

.

Irvine             

Suite  #  D/E

CA  92618

        

Smyrna, GA 30080

TOLL-FREE  PHONE NUMBER: (877)886-5989

Summary of Contents for EL250TYLA-B

Page 1: ...f sale not for pur pose of resale from the manufacturer Safety Information Warnings 2 Air for Combustion and Ventilation 4 Installation 6 Operating heater 9 Cleaning Maintenance 10 Trouble Shooting 11...

Page 2: ...d in a bedroom or bathroom erating heater 5 Do not use this heater as a wood burning heater Use only the logs pro vided with the heater 6 Do not add extra logs or ornaments such as pine cones vermicul...

Page 3: ...ct of gas combustion An unvented room heater productes approximately one 1 ounce 30ml of water for every 1 000 BTU s 3KW s of gas input per hour Unvented room heaters are recommended as supplemental h...

Page 4: ...ining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining...

Page 5: ...Figure 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr This fresh air would come from an adjoining uncon fined space Wh...

Page 6: ...vinyl or cloth wall coverings or operating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may dis color walls IMPORTANT Vent...

Page 7: ...1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur Installation must include an equip ment shutoff valve union and plugged 1 8 NPT tap...

Page 8: ...xture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for lea...

Page 9: ...sition 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information on page 2 If you don t smell gas go to the next s...

Page 10: ...e To Turn Off Gas to Appliance page 9 see Troubleshooting pages 11 through 12 CLEANING AND MAINTENANCE WARNING Turn off heater and let cool before cleaning CAUTION You must keep c o n t r o l a r ea s...

Page 11: ...may become blocked by debris or rust with no flame present If so turn off heater and let cool Either remove blockage or replace burner Blocked burner flame holes will create soot TROUBLE SHOOTING Not...

Page 12: ...1 C l e a n b u r n e r s e e C l e a n i n g and Maintenance page 10 or replace burner orifice 2 Contact local propane LP gas company 3 Replace burner orifice 4 Reconnect leads Delayed ignition burne...

Page 13: ...mensions Inches H W D Stove 38 3 16 26 3 8 14 1 8 Carton 37 29 5 16 15 5 16 41 3 8 x29 5 16 x17 3 8 Weight lbs Stove 73 78 73 78 Shipping 89 94 89 94 For purposes of input adjustment The carton dimens...

Page 14: ...e will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product Call PRO COM at 877 886 5989 for referral information When calling PRO CO...

Page 15: ...1 5 14 ILLUSTRATED PARTS BREAKDOWN EL250TYLA B EL250TYLA W EL250TYLB O EL250TYLA C EL250TYLB DO EN250TYLA B EN250TYLA W EN250TYLB O EN250TYLA C EN250TYLB DO...

Page 16: ...e parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 14 of this manual EL250TYLA B EL250TYLA W EL250TYLB O EL250TYLA C EL250TYLB DO EN250TYLA...

Page 17: ...1 7 16 ILLUSTRATED PARTS BREAKDOWN EL250TYLA B EL250TYLA W EN250TYLA B EN250TYLA W...

Page 18: ...1 8 12 17 PARTS LIST EL250TYLA B EL250TYLA W EN250TYLA B EN250TYLA W...

Page 19: ...1 9 18 ILLUSTRATED PARTS BREAKDOWN EL250TYLB O EN250TYLB O EN250TYLB C EL250TYLB C EN250TYLB DO EL250TYLB DO...

Page 20: ...2 0 19 PARTS LIST EL250TYLB O EN250TYLB O EN250TYLB C EL250TYLB C EN250TYLB DO EL250TYLB DO...

Page 21: ...g logs Fasten decorating logs 1 2 3 onto the correspondent angle iron Figure 4 Insert the pinhole on the upper part of log 4 into the pin on the left side of log 1 Place the lower part on the flat roo...

Page 22: ...ear panel and place it on the mounting bracket in the door Mounting operating control housing to the mounting bracket with two screw see figure 4 B EN L 250TYLBmodel Insert opera tion control housing...

Page 23: ...Power Cord WiringDiagram Decal INSTALLING BLOWER ACCESSORY BLOWER ACCESSORY MODEL NFHTX186 Figure 3 A Routing Power Cord Figure 5 Mounting Control Housing MODEL EL N 250TYLB Figure 4 Mounting Control...

Reviews: