TROUBLESHOOTING
CHEYENNE 86038870 03/14/07
4-5
PROBLEM
CAUSE SOLUTION
Dead electrical circuit
Check building circuit breaker or fuse box.
Loss of Power
Faulty power cord
Replace
Equipment not grounding
Follow grounding instructions exactly
Receptacle not grounded
Contact an electrician to check building’s wiring
Electrical shock
Internal wiring problem
Have a trained service technician check machine’s
wiring
Worn motor brushes
Replace
Motor worn out
Replace
Vac motor speed varies
or doesn’t run
Faulty switch
Replace
Loose vacuum dome
Center and seal dome over tank
Crack in dome of poor joint Replace or repair using acrylic plastic cement only
Lint or dirt clogging
vacuum screen
With power off clean screen
Loose cuffs on vacuum
hose
Tighten cuffs turning counterclockwise
Vac motor seals leaking
Replace
Floor tool vac chamber
clogged
Wash out with hose. Pick lint out with a wire
Loss of vacuum
Vac motor, hose, or dome
gasket
Replace
Pump inlet screen plugged
Clean inlet screen
Pump air locked
Press trigger to open valve on cleaning wand to
relieve air
Pump runs no solution
Internal or external
solution line damaged and
leaking
Replace
Internal pump components
wearing out
Replace, see pump kit components (Pg 4-3)
Pump runs, loss of
pressure
Check BPR for particles or
cuts in seals
Take piston from BPR and lubricate with Superlube.
If problem still exists change BPR.
Unit not plugged in
Connect unit to 3 prong grounded outlet
Pump will not run
Loose wiring
See dealer
Solution hose fitting hard
to connect
Corrosion on fittings.
Clean with steel wool. Soak in acetic acid (white
vinegar). Lubricate lightly with silicone base lubricant.
Carpet not getting clean
Severe soil conditions
Make several passes at right angles to each other.
Use a pre-spray.
Carpet too wet
Over saturation
Check solution wand. Make several passes without
spray
Leaving carpet too wet
Check for loss of vac pressure
Too much chemical
Check label for correct solution concentration
Carpet browning
Light carpet with no brown
prevention
Go over carpet with browning prevent only
Solution hose connection
Check for positive connection
Faulty pump
Repair or replace
Faulty floor tool valve
Repair or replace
Solution not flowing
properly
Faulty pump switch
Repair
Summary of Contents for 100075230
Page 17: ...CHEYENNE 86038870 03 14 07 4 6 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 18: ...BASE GROUP CHEYENNE 86038870 03 14 07 5 1 6 4 5 3 2 1 8 5 7 8 6 7 6 9 5 ...
Page 24: ...RECOVERY TANK GROUP NO HEAT CHEYENNE 86038870 03 14 07 5 7 1 2 3 4 5 6 7 8 10 9 11 12 13 11 ...
Page 26: ...RECOVERY TANK GROUP WITH HEAT CHEYENNE 86038870 03 14 07 5 9 1 11 3 4 5 6 7 8 10 9 11 12 13 2 ...
Page 32: ...VACUUM GROUP 2 STAGE CHEYENNE 86038870 03 14 07 5 15 1 2 3 4 5 12 4 3 6 8 9 7 2 6 6 10 11 ...
Page 34: ...VACUUM GROUP 3 STAGE CHEYENNE 86038870 03 14 07 5 17 1 2 3 4 5 12 4 3 6 8 9 7 2 6 6 10 11 ...
Page 38: ...LABEL STRAP GROUP CHEYENNE 86038870 03 14 07 5 21 1 2 3 ...
Page 40: ...WIRE GROUP MACHINE LEVEL CHEYENNE 86038870 03 14 07 5 23 ...