background image

Page 1

Page 4

VHF/UHF Amplifiers

PD

2011-9003-04

INSTALLATION INSTRUCTIONS

This range of six amplifiers is ideal for use in small domestic and commercial reception and distribution

systems. The proAMP24, proAMP26 and proAMP28 are traditional 4-, 6- and 8-way aerial signal

amplifiers. The ‘R’ versions have a 6 MHz return path, for use with infra-red remote control extender

systems of the type which connect to the RF OUT-2 output of a Sky* Digibox.

Features – whole range

n

Separate inputs for FM radio (87.5 – 108 MHz) and UHF TV (470 – 862 MHz).

n

4-, 6- and 8-way versions available.

n

Suitable for digital reception systems.

n

Low noise figure and high output capability.

Features – proAMP24, ‘26 and ‘28

n

Line power available at UHF input – 12 V at up to 100 mA.

n

Higher-gain FULL output on 6- and 8-way versions allows expansion beyond eight points.

n

‘IEC’ connectors.

Features – ‘R’ versions

n

6 MHz return path for Sky* IR remote control systems.

n

Built-in power for IR ‘eyes’ on all outputs.

n

‘F’ connectors.

Note: ‘R’ versions do not have input line-power capability or FULL outputs.

Fixings

Fix the amplifier to a sound vertical surface such as a wall or equipment mounting board. Ventilation

gaps of at least 30 mm should be left around the front and all sides of the unit. More clearance will be

required below and to the right of the unit to allow access for the signal cables.

Do not leave the amplifier resting on a carpet or install it where it may become smothered

with curtains or other soft furnishing fabrics. When installing the amplifier in a roof space

ensure that it will not come into contact with thermal insulation material.

Signal connections

To preserve RF screening integrity the signal connections to the amplifier should be made using good

quality coaxial cable and connectors. This is particularly important with digital terrestrial TV (DTT) to

minimise the ingress of impulsive electrical interference from home appliances.

n

The use of cable ‘benchmarked’ under the CAI scheme is recommended.

n

Amplifiers proAMP24, proAMP26 and proAMP28 require ‘IEC’ connectors (IEC 60169-2).

n

Amplifiers proAMP24R, proAMP26R and proAMP28R require Type-F connectors (IEC 60169-24).

For both connector types the use of crimp connectors, used in accordance with the manufacturer’s

instructions will give the best results. The importance of achieving sound braid connections cannot be

over-stressed.

Important:

 the FULL output (where fitted) must always be terminated in a well-matched 75 

Ω

 load.

The terminator plug supplied 

must

 be fitted if this output is not used. (See also the section headed

“Using the FULL output”

.)

Proception Limited,

177-187 Rutland Road

SHEFFIELD

S3 9PT

United Kingdom
Web:

http://www.proception.co.uk/

e-mail: [email protected]

Performance data given are typical unless otherwise stated. Proception Limited reserves the right to change

product designs and specifications without prior notice.

Safety Instructions

OVERHEATING
The recommended ventilation clearances and other precautions given in the relevant section

of this instruction leaflet should be observed to prevent overheating. No unit should be

fixed where it is likely to become smothered by soft furnishing fabrics such as curtains, or by

thermal  insulation  material  in  a  roof  space  or  building  void.  Mains  powered  equipment

should not be left resting on a carpet.
WATER AND FIRE RISKS
The appliance is not waterproof. It is intended for indoor use only and must not be fixed

where it could be exposed to dripping or splashing water. Objects containing liquids should

not be placed on or near the appliance.
To prevent risk of fire, no object with a naked flame should be placed on or near the appliance,

or its associated wiring.
MAINS PLUG
The appliance is supplied with a standard fused plug fitted. If this is unsuitable, refer to the

instructions below. If you need to change the fuse in the fitted plug, a 3 Amp fuse to BS

1362 carrying the ASTA or BSI approval mark must be used. Always replace the plastic fuse

carrier when renewing the fuse.
CHANGING THE PLUG
If the fitted mains plug is not suitable for the socket-outlets in use, it should be cut off and

a new plug fitted.
Wiring  the  New  Plug:  Instructions  supplied  with  the  new  plug  should  be  followed.  The

brown wire must be connected to the live (L) terminal of the plug and the blue wire to the

neutral (N) terminal. Neither wire should be connected to the earth (E) terminal of a 3-pin

plug (the appliance does not require an earth connection). Ensure that the cord grip in the

plug is correctly used and clamps the sheath of the cord firmly.
Fuse Rating: If the new plug is a fused type, the fuse fitted should be rated at not more than

3 Amp.
Caution:  The  old  plug  should  be  destroyed  immediately  since  it  would  be  dangerous  if

plugged into a live socket.

proAMP24 & ‘24R

proAMP26 & ‘26R

proAMP28 & ‘28R

2-Year Guarantee

This guarantee covers failure of your 

PRO

ception product resulting from manufacturing defect

within a period of 2 years from the date of supply to the end-user. This guarantee does not

cover damage to the product caused by abuse, tampering, defective installation or natural

causes such as lightning discharge. Repair or attempted repair, other than by the manufacturer,

will render this guarantee void. This guarantee does not affect a consumer’s statutory rights.

PRO

ception

* “Sky” is a registered trademark of British Sky Broadcasting Group PLC.

Reviews: