background image

Declaration of Conformity 

VPH 150 

V5 

 

10/01/13 

5 / 23 

 

 

 

DIN EN 60204-1

   (IEC 60204-1)

 

Safety of machinery, electrical equipment of industrial machines. Part 1: 

General requirements

 

 

 

2006/95/EG

 

(Low voltage standard)

 

 

 

2004/108/EG

 

(Electromagnetic compatibility) 

 

 

DIN EN 55014-1

   (IEC/CISPR 14-1)

 

Electromagnetic compatibility – Requirements for household appliances, electric tools, and similar apparatus.  
Part 1: Emission. 

 

DIN EN 55014-2

   (IEC/CISPR 14-2)

 

Electromagnetic compatibility – Requirements for household appliances, electric tools, and similar apparatus.  
Part 2: Immunity. 

 

 

 

 

 

 

 

 

 

Authorized person for EC-dokumentation: 

 

Name: J. Holderied

 

Adress: Probst Greiftechnik

Verlegesysteme GmbH; Gottlieb-Daimler-Str. 6; D-71729 Erdmannhausen 

 

 

 

Signature: 

Erdmannhausen, 10.01.2013.......................................................................... 
(M. Probst, Managing director) 
 

Summary of Contents for VPH-150

Page 1: ...Vacuum Power Handy VPH 150 5 Vacuum Power Handy VPH 150 V5 Serial No Order No 5271 0001 Translation of original operating instructions...

Page 2: ...or Installation Maintenance and Operating Personnel 11 4 4 1 General 11 4 4 2 General 11 4 5 Special Hazards 12 4 6 Instructions for the Operator 12 4 7 Personal Protection Equipment 12 4 8 Behaviour...

Page 3: ...g 17 6 3 Repairs 18 6 4 Safety procedures 18 6 5 Hints to the identification plate 19 6 6 Hints to the renting leasing of PROBST devices 19 7 Vacuumpump 20 7 1 General 20 7 2 Safety Advice 20 7 3 Desc...

Page 4: ...o probst eu www probst eu Complies with the following provisions applying to it EC machinery directive 2006 42 EG DIN EN ISO 12100 Safety of machinery General principles for design Risk assessment and...

Page 5: ...tromagnetic compatibility Requirements for household appliances electric tools and similar apparatus Part 1 Emission DIN EN 55014 2 IEC CISPR 14 2 Electromagnetic compatibility Requirements for househ...

Page 6: ...plate Never exceed the stated maximum load The stated maximum load can only be achieved with a vacuum of at least 500 mbar Never exceed the permitted maximum load of 150 kg Prohibition The device is...

Page 7: ...lifting especially take care with thin and large sized stone slabs Generally the load stones slab is only to be sucked in the middle otherwise the load hangs diagonally under the device and the load c...

Page 8: ...13 8 23 3 2 Survey and construction 3 3 Technical data Type Carying capacity kg valve at 500 mbar under pressure Dead weight kg VPH 150 150 16 5 Handles Suction filter Suction hose Foot Suction plate...

Page 9: ...result Prohibition Prohibition Identifies imminent a prohibition If you do not avoid the prohibition death and severe injury or damage to property will result 4 2 Definition skilled worker specialist...

Page 10: ...r hanging loads Danger to life 2904 0101 Do not lift any components off centre 2904 0383 102x52 mm WARNING SIGN Symbol Meaning Order No Size Danger of pinching the hands 2904 0221 2904 0220 2904 0107...

Page 11: ...ot use the device until all faults which can cause safety hazards are removed If there are splits at carrying parts of the device immediately stop using it The operating instructions must be available...

Page 12: ...herwise leave the danger area below the load immediately The unit draws in large amounts of air and hair and items of clothing can be drawn into the air inlet Do not look into the air inlet when the u...

Page 13: ...re gauge Checking the Pressure Gauge Switch on the VPH Place the VPH onto a metal plate or similar and suction A Valve at 0 5 bar under pressure must be reached Checking the suction hose and clamps Co...

Page 14: ...city of the suction plate 5 3 General Prohibition Danger Do not let go off the handle of the device VPH whilst a load is being lifted Never pull the load diagonally or drag it Do not try to free loads...

Page 15: ...Loads Lower the load and place it on clear even surfaces so that the load does not slip or tip Switch off the diaphragm pump using the main ON OFF switch Caution Once the machine is switched off the s...

Page 16: ...e care that the tightening torques according to the property class of the screws are observed Check all joints bolts guidance s and gears for correct function if necessary adjust or replace it Check a...

Page 17: ...e air filter and the fittings such as pipe clips etc and make sure they are tightly sealed ON OFF switch Make absolutely sure that the ON OFF switch is working ok wires on solinoid valve Check the wir...

Page 18: ...6 4 Safety procedures It is the contructors responsibility to ensure that the device is checked by an expert in periods of max 1 year and all recognized errors are removed BGR 500 The corresponding r...

Page 19: ...hich can be handled with the device Do not exceed this carrying capacity If you use the device in combination with other lifting equipment Crane chain hoist forklift truck excavator consider the deadw...

Page 20: ...damp When opening covers or removing parts except for when this can be done by hand live parts can be exposed Connections can also be live Before carrying out any maintenance work repairs or replacing...

Page 21: ...w charged the battery is Yellow LED above 14 5 Volt Voltage Battery is overcharged Green LED 11 5 14 5 Volt Voltage Normal Red LED under 11 5 Volt Voltage Battery needs charging On the underpart of th...

Page 22: ...ry falls under 11 5 Volt the red LED will light up The battery will then need recharging When you have finished switch off the machine and remove the hoses in compliance with all regulations 7 4 Maint...

Page 23: ...70 2 2 Way Solenoid Valve 12V 6 5 Watt Solenoid Part Device Diaphragm NBR Perbunan Valves Neopren Pump Casing Glass fibre reinforced polyamide Solenoid Valve Casing Brass Hoses internal Silicone Hoses...

Page 24: ...7 8 F E D C B 1 19 4 kg Schutzvermerk nach DIN 34 beachten Nachdruck nur mit unserer Genehmigung Gewicht Bei nderungen R cksprache TB Kunde WA 2 Mann Bedienung 1 Perumal Hurth 7 9 2011 Gepr Erst Name...

Page 25: ...zvermerk nach DIN 34 beachten Nachdruck nur mit unserer Genehmigung 16 7 kg 1 Werkstoff Pos Stck Art Nr Beschreibung L nge Breite Gewicht Material Vers 1 1 42710001 Vakuumpumpen Einheit VPE 0 5 E 12 G...

Page 26: ...VPH 42710004 Ansaugfilter f r VPH Air filter for VPH 150 Air filter for VPH 150 42710020 Innenfilter f r VPH VPH Internal Filter VPH Internal Filter...

Page 27: ...410 0162 Protection hood for switch 1x 2410 0164 Frame for switch 1x 2410 0165 Security part 1x 2410 0166 Fuse 1x 2436 0007 LED indication 1x 2410 0167 Din plug for charger 1x 2410 0168 Plug 1x 2420 0...

Page 28: ...akuum Power Handy VPH 150 Art Nr 5271 0001 05 2012 2530 0008 2410 0165 2410 0166 4271 0005 2213 0019 4271 0019 4271 0004 Zubeh rteil Akkuadapterkabel mit Klemmen EYU0001 000 2412 0018 2410 0154 2410 0...

Page 29: ...71729 Erdmannhausen Tel 07144 3309 0 Fax 07144 3309 50 e mail info probst gmbh de Internet www probst gmbh de M M 1 2 Bordspannungs berwachung 12 V 12 V Schalter 0 1 Magnet Ventil Akku 12 V Sicherung...

Page 30: ..._ _ _ _ _ _ _ _ Article No _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Device No _ _ _ _ _ _ _ _ _ _ _ _ Year of make _ _ _ _ First inspection after 25 operating hours Date Maintenance work Inspection by company Co...

Page 31: ..._ _ _ _ _ _ _ _ Article No _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Device No _ _ _ _ _ _ _ _ _ _ _ _ Year of make _ _ _ _ First inspection after 25 operating hours Date Maintenance work Inspection by company Co...

Page 32: ..._ _ _ _ _ _ _ _ Article No _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Device No _ _ _ _ _ _ _ _ _ _ _ _ Year of make _ _ _ _ First inspection after 25 operating hours Date Maintenance work Inspection by company Co...

Reviews: