Vacuumpump
VPH 150
V5
10/01/13
22 / 23
7.3.1
Charge battery
To ensure the perfect working of the pump, it is important that the lead rechargeable battery is always
charged up.
To charge the battery:
Proceed as follows:
●
Set the main switch to 0.
●
Remove the lead hoses (suction hose)
●
Insert the battery charger on the underside into the in-built socket.
●
Plug the battery charger into the 220 Volt mains.
Once the battery has been successfully charged, disconnect the battery charger.
Put the connection hoses in and switch on the pump at the main switch.
(if everything is okay, the green LED will light up on the charging control panel).
As soon as the in-built battery falls under 11,5 Volt, the red LED will light up. The battery will then need
recharging.
When you have finished, switch off the machine and remove the hoses (in compliance with all regulations).
7.4
Maintenance
The pump is basically maintenance-free.
All necessary spare parts are available for the vacuum pump.
Repaires should be only carried out by authorized experts.
Disconnect from the mains before starting any repairs.
The diaphragms are the parts which will wear out first. When replacing the diaphragms, the valves and the
seals should also be replaced.
As and when required, it would pay to use suitable filters in order to improve the life of the pump
considerably.
MAKE SURE THAT THE BATTERY IS NEVER TOTALLY FLAT.
REMEMBER THAT WHEN THE MACHINE IS NOT IN USE, THE BATTERY WILL STILL BE GOING FLAT.
MAKE SURE THAT NO LIQUIDS OR SOLIDS GET INTO THE PUMP.