Maintenance and care
52400045 / 52400049
26 / 29
GB
6
Maintenance and care
6.1
General Hints
The device may be installed and maintained only by qualified personnel such as mechanics and electricians.
All work on the electrical system may only be done by qualified electricians.
Always disconnect the electric power before starting any maintenance work.
The fans must not be opened during the guarantee period as this will entail loss of guarantee cover.
After any repair or maintenance work, check the safety devices as described in the section "Safety".
To ensure the correct function, safety and service life of the device the following points must be executed in
the maintenance interval.
Used
only original spare parts
, otherwise the warranty expires.
All operations
may only be made in unpressurised, electro less and closed state of the device!
6.2
Maintenance Plan
Interval
Daily
Weekly Monthly Every 6
months
Every 12
months
Inspect the safety devices:
- Vacuum gauge OK?
X
X
Electrical equipment OK? Cable glands tight?
X
All connections (hose clamps, etc.) tight?
X
Instruction plate, rating plate and load plate still mounted on
the device?
X
Operating instructions available?
Operating personnel familiar with operating instructions?
X
Inspect load-carrying part (such as suspension) for
deformation, wear and other damage.
x
Clean and inspect suction pads. Must be free of cracks, lip
must be smooth, etc. Replace if necessary.
X
X
Clean the air filter
X
Is the inspection sticker up to date?
X
General condition of the device.
X
Leak test
X
X