58
Figure 33. Move coupling with pry bar to test alignment of auger and bearing
6.8 WEAR PLATE REMOVAL AND INSTALLATION
Note: Wear plates should be replaced when the distance between the outer edge of the wear plate and the auger screw
flighting is within 1/8 inch. In general, wear plate replacement should take place before the auger flighting shows signs
of wear.
Note: The auger screw should be replaced when the distance between the outer edge of the auger flighting and bolt
HOLE is within 1/8 inch. When the auger flighting has worn to the bolt holes, the entire auger screw will need to be
replaced (PN MX10803).
Figure 34. Worn auger wear plates in need of replacing