5.7 ELECTRICAL
5.7.1 SOLENOID INDICATORS
The hydraulic solenoid valves have connectors that light
up when power is applied. This is a useful tool in
troubleshooting and can be used as a quick visual indication
that a function is being actuated.
Each wire is also labeled with the associated function name
. This label can be used to verify if the correct cable is
connected to the correct valve or just for general valve
identification.
5.7.2 CONTINUITY AND CURRENT DRAW
The current draw for individual functions can be found in
the Electrical Diagnostics screen. By touching the function
name a green box will appear allowing the user to rotate
the knob on the display and select the desired functions
current output.
The output is shown in mA and is available to all functions
that use variable output signals including higher current
outputs such as the admix pumps.
Power module status shows error codes from the power
module. This includes open and short circuits. This applies
to vibrators and the admix pumps that are powered by this
module.