5.4.6 COLOR
Although the color feeder is not considered a pozzolan
metering system in the Commander computer it does
function in the same way as the cement and AUX1 metering
systems.
The diagnostics steps are the same as the primary cement
metering system.
The color feeder also typically runs at much lower speed
ratio then the cement, so also be careful of low (<10RPM)
setpoints. If the speed setpoint is low, increase your belt
speed as high as you can. This will increase the color
speed setpoint at the same time.
The Commander control system will warn the mix design
creator / operator when the speed ratio goes below 15% by
changing the text to red.