pg. 18
Operator’s Manual,
Ranger Gunite r1.0
1.10 DIAGNOSTICS
1.
Menu shortcut. Return to the main menu.
2.
Home shortcut. Return to the home screen.
3.
Hydraulic pressure. Shows current outlet pressure on the main pump. Also shows auxiliary pump pressure if
equipped with hydraulic gunite pump outputs.
4.
Oil temperature. Shows current hydraulic oil temperature.
5.
Oil temperature units can be changed here.
6.
Hydraulic pressure units can be changed here.
7.
Alarm log. Screen showing the history of alarms.
See page 19
.
8.
CANBUS and input device diagnostics. Any device on the CANBUS communication network is monitored to ensure
it is sending data to the computer. If the indicator is red then the device either does not exist (optional component)
or there is a fault/disconnect somewhere in the system.
9.
CAN Reset is used to initialize or reset the CAN devices' communication parameters. Typically used when installing
a new device.
10.
Voltage at the input pin of ECU/computer.
11.
Individual electrical device current draw can be checked here. Touch the name in blue and use the up/down touch
keys to select a device to monitor. The current draw is in milliamps.
1
2
4
3
7
5
6
10
11
9
8