ProAir Electra Kool Service Manual Download Page 1

 

2900 County Rd 6 W~ Elkhart, IN 46514

 

574-264-5494/Toll Free: 800-338-8544/Fax: 547-264-2194 

 

 

 
 

Service Manual 

For

 
 

 
 
 

Rooftop RV Air Conditioner 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Electra Kool

Page 1: ...2900 County Rd 6 W Elkhart IN 46514 574 264 5494 Toll Free 800 338 8544 Fax 547 264 2194 Service Manual For Rooftop RV Air Conditioner ...

Page 2: ...ART NUMBER 09 000 545 2 P a g e Table of contents Warning and Safety Statement Cool Mode operation Maintenance Troubleshooting Chart Wire Schematic Unit Drawing 50 001 911 Plenum Drawing 52 001 125 Warranty Registration Warranty Procedure Warranty Checklist Page 3 4 5 5 6 7 12 8 10 11 12 13 13 14 ...

Page 3: ...ry Always wear eye protection and protective clothing and use extremecare when opening valves and removingcaps gauges refrigerant lines etc May Start Automatically All Electric units have an auto start feature that may start the system without warning Keep all service doors closed and guardsin placewhen not working on the unit Place the unit ON OFF switch in the OFF position and disconnect the neg...

Page 4: ...ditional Safety Tips Observe your shop s lock out I tag out requirements Truck ignition keys must be secured and the wheels chocked Use extreme caution when working on ladders and work platforms Use ladders and or overhead harnesses in the manner prescribed by the manufacturer of these products Do not wear a wrist watch rings or other jewelry while working on or around equipment These items may ca...

Page 5: ... from filter with vacuum and wash filter with soap and water Filter should be cleaned once a month during normal conditions and daily or weekly if conditions are warranted Note Never run the air conditioner without the return air filter Running the air conditioner without a filter may allow the evaporator coil to be plugged with dirt which will affect the performance of the air conditioner Condens...

Page 6: ... Contact ProAir for service options UNIT NOT COOLING CONDENSER FAN AND COMPRESSOR NOT RUNNING 1 Check to make sure control panel is in COOL mode 2 Set desired thermostat temperature on controller below inside ambient temperature 3 Check for blown 20 AMP condenser fuse FIGURE 2 behind return air filter 4 Check harnesses to ensure wires going in and out of connectors match and are inserted into conn...

Page 7: ...PRODUCT 12v Rooftop RV Operation Service Manual RELEASE DATE 1 4 19 REVISION DATE 1 4 19 Rev A PART NUMBER 09 000 545 7 P a g e ABC F E DC BA ...

Page 8: ...PRODUCT 12v Rooftop RV Operation Service Manual RELEASE DATE 1 4 19 REVISION DATE 1 4 19 Rev A PART NUMBER 09 000 545 8 P a g e ...

Page 9: ...PRODUCT 12v Rooftop RV Operation Service Manual RELEASE DATE 1 4 19 REVISION DATE 1 4 19 Rev A PART NUMBER 09 000 545 9 P a g e ...

Page 10: ...PRODUCT 12v Rooftop RV Operation Service Manual RELEASE DATE 1 4 19 REVISION DATE 1 4 19 Rev A PART NUMBER 09 000 545 10 P a g e ...

Page 11: ...PRODUCT 12v Rooftop RV Operation Service Manual RELEASE DATE 1 4 19 REVISION DATE 1 4 19 Rev A PART NUMBER 09 000 545 11 P a g e ...

Page 12: ...PRODUCT 12v Rooftop RV Operation Service Manual RELEASE DATE 1 4 19 REVISION DATE 1 4 19 Rev A PART NUMBER 09 000 545 12 P a g e ...

Page 13: ...ir reserves the right to supply any and all warranty parts 4 All warranty parts are shipped on a memo no charge billing and are sent the same day if possible An authorization number accompanies the replacement parts Also noted on the memo billing is our labor allowance for the repair labor allowances are based on ProAir s flat rate standards multiplied by the repair facility s standard retail labo...

Page 14: ...PRODUCT 12v Rooftop RV Operation Service Manual RELEASE DATE 1 4 19 REVISION DATE 1 4 19 Rev A PART NUMBER 09 000 545 14 P a g e ...