PRO SIGNAL PSG04174 Manual Download Page 1

y

 

Do not expose the main unit to rain or moisture 

y

 

Use only recommended batteries 

y

 

Remove the batteries if the weather station is not to be used for a 
long time. Old batteries can begin to leak and damage the product. 

y

 

Remember to insert the batteries according to the markings in the 
battery compartment. The wrong polarity (+/-) can damage the 
weather station. 

y

 

Damage that has occurred by careless handling is not covered by 
the 

warranty.

 

Production Description. 

y

  Display of indoor and outdoor temperature, wind speed, wind 

direction, humidity, rainfall amounts, time and date 

y

 

Alarm function for certain weather conditions as well as records of 

1

 

Wireless Weather

 S

tation 

Model: 

PSG04174

Safety

Summary of Contents for PSG04174

Page 1: ...batteries according to the markings in the battery compartment The wrong polarity can damage the weather station y Damage that has occurred by careless handling is not covered by the warranty Producti...

Page 2: ...onal but only one y Save the data when batteries is changed y Operates on 5x LR6 AA alkaline batteries not included Contents y Main unit Display unit y Outdoor unit LCD Display The following illustrat...

Page 3: ...ture 14 Indoor humidity high alarm and low alarm 15 Indoor humidity 16 Rainfall unit 17 Outdoor temperature high alarm and low alarm 18 Outdoor temperature 19 Outdoor reception signal 20 Outdoor Humid...

Page 4: ...ro sensor 4 Rain collector 5 Bubble level 6 Solar panel 7 Antenna 8 U Bolt 9 Battery compartment 10 Reset button 11 LED Indicator lights for 4 seconds when the unit powers up Then the LED will flash o...

Page 5: ...e the other side is bent at a 90 degree angle and has a curved profile which will end up hugging the mounting pole Once the metal plate is inserted insert both U bolts through the respective holes of...

Page 6: ...ly There should be no noticeable friction when it is turning Figure 5 Wind speed cup installation diagram 3 Install wind vane Push the wind vane onto the shaft on the opposite side of the wind cups un...

Page 7: ...crewdriver and insert 2 AA batteries in the battery compartment The LED indicator on the back of the sensor package will turn on for four seconds and then flash once every 48 seconds indicating sensor...

Page 8: ...tailed in this section you may want to skip to the setup instructions first while you keep the assembled outdoor sensor package nearby although preferably not closer than 5 ft from the console This wi...

Page 9: ...just the mounting pipe as necessary If the bubble is close but not quite inside the circle and you cannot adjust the mounting pipe you may have to experiment with small wooden or heavy cardboard shims...

Page 10: ...Frequency Interference RFI If you have other 433 868 915 MHz devices and communication is intermittent try turning off these other devices for troubleshooting purposes You may need to relocate the tra...

Page 11: ...itter the radio reception icon will be turned on Do not press any key before outdoor sensor data received otherwise the outdoor sensor learning mode will be terminated When outdoor transmitter has bee...

Page 12: ...receiver and transmitter in the open field can reach a distance of up to 330 feet providing that there are no interfering obstacles such as buildings trees vehicles high voltage lines etc Radio interf...

Page 13: ...de Setting Mode Press the SET key for 2 second while in normal mode to enter the Setting mode LCD contrast digits will start flashing You can skip over any setting by press the SET key Press key or MI...

Page 14: ...0 75 to 1 25 y History rainfall Calibration y Outdoor humidity Calibration y Outdoor temperature Calibration y Indoor humidity Calibration y Indoor temperature Calibration Wind Speed Calibration Wind...

Page 15: ...hours Compare this temperature to the fluid thermometer and adjust the console to match the fluid thermometer Humidity Calibration Humidity is a difficult parameter to measure accurately and drifts ov...

Page 16: ...reset The total is multiplied by 0 3 to get a total in mm This is then converted to inches if necessary by multiplying by 0 0393700787 The calibration multiplier is then applied to this and this is t...

Page 17: ...arm 1 99 8 Outdoor temperature high alarm 40 C 60 C 9 Wind chill high alarm 40 C 60 C 10 Dew point high alarm 40 C 60 C 11 Indoor humidity high alarm 1 99 12 Indoor temperature high alarm 9 9 C 60 C I...

Page 18: ...tion was activated again within 3 hours alarm will not sound but will continue to flash until weather conditions have become more steady This feature is useful to avoid repeated triggering for the sam...

Page 19: ...time and date at which these values were recorded if hold the SET key for 3s in the following individual minimum value will be reset to current reading together with the current time and date 1 Outdoo...

Page 20: ...ide range Accuracy 1m s wind speed 10m s 10 wind speed 10m s Measuring interval thermo hygro sensor Water proof level Indoor data Measuring interval temperature humidity Indoor temperature range if ou...

Page 21: ...eed to change the transmitter batteries The low battery indicator will work normal when the outdoor temperature rise to 10 35 21 Maintance 1 Clean the rain gauge once every 3 months Rotate the funnel...

Page 22: ...is required Do not dispose of these items with general household waste Separate for the treatment recovery and recycling of the materials used Waste batteries can be returned to any waste battery rec...