background image

V1.0 

 

8689507 

Please read and understand all instructions before use. Retain this manual for future reference. 

SPECIFICATIONS 

Rated Input Flow 

12 GPM 

Maximum Pressure 

3,000 PSI 

Internal Leakage 

0.022 cu. in/min @  

3,000 PSI 

Filtration Requirement  10 Micron minimum 
Temperature Range 

-30°C to 120°C  
(-22°F to 250°F) 

Port Size 

8 ORB 

 

INTRODUCTION 

The High Pressure Needle Valve restricts or 

shuts off the hydraulic oil flow within a 

hydraulic circuit. Turning the handle clockwise 

will restrict the oil flow until shutting it off 

completed. The hydraulic circuit design must 

account for the pressure load upstream of the 

closed valve. 
 
 
 

SAFETY 

WARNING! Read and understand all 

instructions before using this device. The 

operator must follow basic precautions to 

reduce the risk of personal injury and/or 

damage to the equipment. 

Keep this manual for safety warnings, 

precautions, operating or inspection and 

maintenance instructions.  
1. 

Use the correct device for the job. This 

device was designed for a specific function. 

Do not modify or alter this device or use it 

for an unintended purpose. 

2.  Operate in a safe work environment. 

Keep your work area clean, well-lit and free 

of distractions. 

3.  Do not operate any device when tired 

or under the influence of drugs, alcohol 

or medications. 

4.  Always wear impact safety goggles that 

provide front and side protection for the eyes. 

Eye protection equipment should comply 

with CSA Z94.3-07 or ANSI Z87.1 standards 

based on the type of work performed. 

5.  Wear protective clothing designed for the 

work environment and device.  

6.  Consult the safety precautions for your 

hydraulic system when installing and 

operating this valve.  

 
 
 
 

UNPACKING 

WARNING! Do not operate the device if any 

part is missing. Replace the missing part before 

operating. Failure to do so could result in a 

malfunction and personal injury. 

Remove the parts and accessories from the 

packaging and inspect for damage. Make sure 

that all items in the parts list are included. 
Contents: High Pressure Needle Valve 

ASSEMBLY & 

INSTALLATION 

Install the valve at a point in 

the hydraulic circuit where 

you wish to restrict or stop 

the flow of oil. Install the 

valve so the oil flows into Port 

1 and out of Port 2.  
 

12 GPM HIGH PRESSURE NEEDLE VALVE 

Reviews: