SPECIFICATIONS 

Rated Input Flow 

8 GPM 

Maximum Pressure 

3,000 PSI 

Adjustable Pressure Range  400 to 2,100 PSI 
Preset Pressure 

2,100 PSI 

Filtration Requirement 

10 Micron minimum 

Temperature Range 

-30°C to 120°C  
(-22°F to 250°F) 

Port Size 

8 ORB 

 

INTRODUCTION 

The Pressure Reducing Valve decreases the 

hydraulic oil pressure on downstream 

components such as a cylinder or motor that 

require a pressure reduction to operate. 

SAFETY 

WARNING! Read and understand all 

instructions before using this device. The 

operator must follow basic precautions to 

reduce the risk of personal injury and/or 

damage to the equipment. 

Keep this manual for safety warnings, 

precautions, operating or inspection and 

maintenance instructions.  
1. 

Use the correct device for the job. This 

device was designed for a specific function. 

Do not modify or alter this device or use it 

for an unintended purpose. 

2.  Operate in a safe work environment. 

Keep your work area clean, well-lit and free 

of distractions. 

3.  Do not operate any device when tired 

or under the influence of drugs, alcohol 

or medications. 

4.  Always wear impact safety goggles that 

provide front and side protection for the eyes. 

Eye protection equipment should comply 

with CSA Z94.3-07 or ANSI Z87.1 standards 

based on the type of work performed. 

5.  Wear protective clothing designed for the 

work environment and device.  

6.  Consult the safety precautions for your 

hydraulic system when installing and 

operating this valve.  

UNPACKING 

WARNING! Do not operate the device if any 

part is missing. Replace the missing part before 

operating. Failure to do so could result in a 

malfunction and personal injury. 

Remove the parts and accessories from the 

packaging and inspect for damage. Make sure 

that all items in the parts list are included. 
Contents: Pressure Reducing Valve 
 

ASSEMBLY  

1. 

Connect the hose from 

the pump side of the 

hydraulic circuit to the 

reducing valve's Port 1. 

2.  Connect the hose from 

the hydraulic circuit 

section that needs a 

pressure reduction to 

the reducing valve's 

Port 2 

3.  Connect the reducing valve's port 3 to the 

reservoir, either directly or with a return 

hose. 

4.  Set the pressure by turning the 

adjustment screw inward to increase 

pressure and outward to decrease 

pressure. One full turn will 

increase/decrease pressure by approx. 

360 PSI. 

 